Why SMD Fuses Sometimes Show High Resistance Without Opening

Engineers at Shenzhen Joincircuit Industrial Co., Ltd. explain it this way. The operating principle of a tubular fuse is familiar to most designers. In a tubular fuse, an overcurrent breaks the thermal balance of the element; once the element reaches the melting point of the metal, the central part of the element changes from solid to liquid.
 
 
Surface tension and gravity then act on the molten metal suspended in the middle of the element: the liquid contracts towards both ends and drips away, while the arc struck by the circuit voltage keeps raising the element temperature. Each arc and each further separation step eventually interrupt the circuit completely.
 
 
That is how a tubular fuse operates.
 
 
The same holds for surface-mount (SMD) fuses, which operate on the same principle. Their construction is different, however: the molten element is tightly enclosed by polymer or ceramic material, so the molten metal cannot contract towards both ends. It can only diffuse into, penetrate, or be absorbed by the surrounding material.
 
 
If the overcurrent stops or disappears during this process (as with a very short pulse) while diffusion and absorption are still going on, the result is a rise in resistance without a complete melt-through of the element.
 
 
What are the consequences? The overcurrent is already gone and the circuit has not been harmed, so the fuse has still done its job. The element has not opened, but its capacity has been reduced; a second overcurrent will melt through it more readily, so protection is still provided. (Related reading: How to Select an SMD Fuse)
 
 
If the second overcurrent is again a short pulse, the resistance rises once more without a full break and the element capacity is reduced again, but protection is still maintained. A rise in resistance without a complete break therefore does not impair the protection an SMD fuse provides; as long as the overcurrent lasts long enough, the fuse will open completely.
 
 
Conversely, if a fuse shows no change at all after an overcurrent, its protective function may be defective.
 
 
By comparison, the element of a time-lag tubular fuse is a composite of two or more metals. Under overcurrent the materials also inter-diffuse, which gives the fuse its pulse withstand capability and can likewise produce a rise in resistance. (Recommended reading: Common SMD Fuse Parameters Explained)

上一条:已经是第一条了!

下一条:自恢复保险丝为什么用高分子材料制作?