Technical Terms for Positive Temperature Coefficient PTC Thermistors
Many people are unsure what PTC means when it appears in fuse specifications, and some of the technical terms are easily misunderstood. Below is a guide to the terminology used for positive temperature coefficient (PTC) thermistor products.
Vmax (maximum voltage, or withstand voltage): the highest voltage a polymer PTC thermistor can safely withstand while tripped, under the specified conditions. Above this value the thermistor may break down and will not recover.
Imax (maximum current, or withstand current): the highest current at which a polymer PTC thermistor can trip safely. Above this value the thermistor may be damaged and will not recover.
Trip: the transition of a polymer PTC thermistor from its low-resistance state to its high-resistance state when an overcurrent occurs or the ambient temperature rises. (Related reading: PPTC vs. CPTC)
• IH (hold current): the maximum current a polymer PTC thermistor can carry at 25 °C in still air without tripping. Under the specified ambient conditions the device can carry it indefinitely without switching from the low-resistance to the high-resistance state. (The current through the PTC is too low to self-heat it above its Curie temperature; such a current is called a non-tripping current, and its maximum value is the maximum non-tripping current.)
Pd (typical power dissipation): the total power dissipated by a PTC after it has tripped at 25 °C in still air, obtained by multiplying the leakage current through the PTC by the voltage across the thermistor.
Ttrip (trip time): the time from the onset of the overcurrent until the PTC thermistor has completed its trip. For any given polymer PTC, the higher the circuit current or the ambient temperature, the shorter the trip time.
IT (trip current): the minimum steady-state current at which a polymer PTC thermistor trips within a specified time at 25 °C in still air.
Tr (recovery time): during natural cooling after the PTC thermistor has tripped, the time required for its resistance to fall back to twice the rated zero-power resistance.
Rmin (minimum resistance): the minimum resistance of the PTC before tripping, measured at 25 °C in still air before the device is installed in a circuit.
Rmax (maximum resistance): the maximum resistance of the PTC before tripping, measured at 25 °C in still air before the device is installed in a circuit.
Ambient temperature: the temperature of the still air surrounding a PTC thermistor, or a circuit that contains a PTC thermistor.
Maximum operating ambient temperature: the highest ambient temperature at which a PTC device is expected to work safely. (Recommended reading: How Resettable Fuses Work)
These are the basic technical terms used for positive temperature coefficient PTC thermistor products. We hope this guide makes them clear; if anything is still unclear, contact our online sales team or call us to request samples. Shenzhen Joincircuit Industrial Co., Ltd. welcomes your enquiry.