The test procedure is as follows:
1. Initial resistance (Rimin) measurement: open the package, take out the fuse and measure its internal resistance;
2. Soldering: reflow-solder the fuse onto a PCB provided with lead wires to make electrical testing easier (as shown in the figure above);
3. R1max measurement: let the soldered fuse cool for 1 hour, then measure its internal resistance.
4. Hold current (Ihold) test: use a DC constant-voltage, constant-current source. Set the voltage to the Vmax specified in the datasheet and the current to the specified hold current Ihold, then energize for 60 minutes;
5. Trip current (Itrip) test: use a DC constant-voltage, constant-current source. Set the voltage to the Vmax specified in the datasheet and the current to the specified trip current Itrip, then energize for 5 minutes;
6. Voltage withstand (Vmax) test: use a DC constant-voltage, constant-current source. Set the voltage to the Vmax specified in the datasheet and the current above the specified trip current Itrip, then energize until the fuse has tripped into the protected state and keep it energized for 1 hour; it must neither burn nor crack.
Test criteria:
1. Testing is carried out at a room temperature of 25 °C, with no illumination and no thermal radiation;
2. The initial resistance Rimin must be within the range stated in the datasheet;
3. The resistance after soldering, R1max, must be within the range stated in the datasheet.
4. The fuse passes if it does not trip within 60 minutes at the hold current Ihold;
5. The fuse passes if it trips within 5 minutes at the trip current Itrip;
After the voltage withstand test the fuse shows no burning or cracking, and is judged to have passed.