A time-lag fuse is another name for the slow-blow fuse, and different people describe it in their own way. A time-lag fuse provides both short-circuit and overload protection. The higher the current, the faster it opens; there is no fixed time index. Take a 10 A time-lag fuse as an example: if the load current reaches 30 A it opens within seconds, whereas a load current of 12 A takes several minutes. In electrical terms this behaviour is called "inverse time delay".
A time-lag fuse is also called a delay fuse. Its time-delay characteristic means that it stays intact when a non-fault pulse current appears in the circuit, while still providing protection against prolonged overload. In some circuits the current at the instant of switching is several times, even tens of times, the normal operating current; although the peak is high, it lasts only a very short time. This is what we call pulse current, inrush current or surge current. (Related reading: Why an SMD Fuse Sometimes Shows High Resistance Without Opening)
An ordinary fuse cannot withstand such current: in a circuit like this a standard fuse would most likely prevent the equipment from starting up at all, while a fuse of larger rating would fail to provide effective protection when the circuit is overloaded. A time-lag fuse solves the problem. Its element is made from specially processed materials that absorb energy, and by adjusting the amount of energy absorbed the fuse can both withstand the inrush current and protect against overload.
Standards define the time-delay characteristics, and where the standard characteristics cannot meet the requirement, contact the manufacturer for a solution. By breaking capacity, fuses are classified as high-breaking-capacity and low-breaking-capacity fuses. By shape they include: flat-head tubular fuses (which are further divided into internally soldered and externally soldered types), pointed-head tubular fuses, knife-blade fuses, screw-in fuses, blade fuses, flat-plate fuses, wrap-around fuses and SMD fuses.
The rated voltage should be equal to or greater than the effective circuit voltage, and the breaking capacity should exceed the maximum fault current in the circuit. Check whether a starting current exists in the circuit when the equipment is switched on; a starting current is normal in some circuits, and in such cases time-lag or medium time-lag fuse tubes should be used.
Next, determine the current that a fuse tube must interrupt and the duration of that current (a condition set by the designer according to the protection requirements of the specific circuit). Referring to the I-T curve for the relevant type, take the largest rated current that satisfies the requirement as the upper limit A1.
We hope the introduction above has given you a general understanding of time-lag fuses. The fast-acting/time-lag distinction is in fact one way of classifying fuses by breaking behaviour, which makes fuses easier to understand. That is our explanation for today. Customers are welcome to call us at any time to request samples, and samples can be applied for free. (Recommended reading: Common SMD Fuse Parameters Explained)