What is breaking capacity, and what does it mean in practice? In the fuse industry there is a technical term called breaking capacity, and it draws a very clear line between fuse specifications. In our fuse part numbers, fuses fall into different classes according to their breaking capacity. Below we explain in detail what a fuse's breaking capacity is and what it means.
The breaking capacity of a fuse is a safety rating. It has little to do with the fuse's electrical performance, which is why manufacturers and users often overlook it; some people do not even know that breaking capacity is one of a fuse's technical specifications.
When a current between the conventional non-fusing current and the rated breaking capacity current specified in the relevant standard is applied to a fuse, the fuse should operate satisfactorily without endangering its surroundings. The prospective fault current of the circuit in which the fuse is installed must be lower than the rated breaking capacity current specified in the standard; otherwise, when a fault occurs and the fuse blows, sustained arcing, ignition, destruction of the fuse, melting of the fuse together with its contacts and illegible fuse markings may result. Poor-quality fuses whose breaking capacity does not meet the standard will cause the same hazards in service.
As a safety component, a fuse must keep both the circuit and the other components in it safe at all times, so it must first of all be sufficiently safe itself under all conditions. In particular, no unsafe event may occur while the fuse is operating, and such events include sustained arcing, re-conduction, burning, splashing and explosion. Breaking capacity is one of the ratings that reflect this protective capability. (Related reading: Breaking Capacity and Interrupting Rating of Fuses)
In practical applications, therefore, the breaking capacity of a fuse is a very important technical specification.
Breaking capacity is measured in amperes and represents the maximum current a fuse can safely interrupt. In other words, as long as the over-current in the circuit does not exceed the fuse's breaking capacity, the fuse will safely break the current with no unsafe effect; beyond that, the fuse may still break the current but cannot be guaranteed to do so safely. Breaking capacity is therefore far from an optional specification.
To ensure the safety of a fuse, when selecting one we need to consider not only the necessary performance parameters such as current rating, fusing characteristics, pulse withstand capability and ageing rate, resistance and power dissipation, and temperature derating, but also safety ratings such as breaking capacity, rated voltage and safety approvals. (Further reading: What Is a Fuse's Breaking Capacity and How to Choose a Good Fuse)
For miniature tubular fuses to European specifications, fuses of the same shape and size are available in low-breaking-capacity and high-breaking-capacity versions. The low-breaking-capacity version is rated at 10 times the rated current or 35 A, whichever is greater; the high-breaking-capacity version reaches 1500 A. North American tubular fuses are not divided in this way, and their specified breaking capacity is much higher: 10,000 A at 125 V, and 35 to 1500 A at 250 V, depending on the fuse's current rating.
We hope this gives you a general understanding of a fuse's breaking capacity and of what it means in practice. If anything remains unclear, browse the other articles on this site, which will deepen your knowledge of fuses, or ask our sales staff for a satisfactory answer. (Recommended reading: Understanding a Fuse's Rated Voltage)