A fuse enthusiast with the screen name “Jueying Wuying” wrote to us asking: if a fuse fails after many surge pulses, how can a fuse be made to withstand repeated surge pulses?
A specialist from Shenzhen Joincircuit Industrial Co., Ltd. answers: as is generally known, a fuse blows mainly because the fuse element is melted by the heat released by the overcurrent, and that energy is usually called I2t. Theoretically, if the I2t of the fuse is greater than the energy released by the surge pulse, the fuse can withstand the pulse and will not open. (Related reading: Differences Between Single-Use Fuses and Resettable Fuses)
As we know, fuses with a strong pulse withstand capability are generally time-lag fuses, and they all share this characteristic. So what happens to a fuse after it has survived one pulse? It depends on how much damage the pulse inflicted on it. If the pulse energy is far below the I2t of the fuse, the stress on the fuse is very small and it can take many pulses without breaking; on the contrary, if the pulse energy approaches the I2t of the fuse, the fuse is heavily stressed and will not survive a second pulse.
Every surge pulse therefore causes a certain amount of damage to the fuse, and its pulse withstand capability I2t is reduced by an amount proportional to the pulse energy.
Therefore, if a fuse is to withstand repeated surge pulses, sufficient margin must be kept between the I2t of the fuse and the energy released by the pulses. Different products must withstand a different number of pulses depending on their service life and switching frequency, so customers should choose a fuse according to their own application when using the product data supplied by a manufacturer. (Recommended reading: Effect of Ambient Temperature on Fuse Performance)