Overcurrent Protection with Resettable Fuses in Humidifiers

In the 21st century, as the pace of life has quickened, appliances of every kind keep appearing, especially in summer: air conditioners, refrigerators, electric fans and more. Air conditioners are the most widely used of them, but every benefit has its cost: air conditioning dries the air, and that is where the humidifier comes in. Healthy humidity not only inhibits the growth and spread of germs, it also supports the immune system.
 
 
A humidifier is a household appliance that raises the humidity of a room. It can humidify a given room, or be connected to a boiler or central air-conditioning system to humidify a whole building. Clean tap water flows through the inlet line into the water tank. While the humidifier is running, a pump delivers that water to the water distributor at the top of the unit, which spreads it evenly over the evaporative media. Water seeps down from the top of the media, is absorbed by it and forms an even film of water. When dry air is drawn into the humidifier by the fan, part of the water absorbs heat from the dry air and vaporises, so the air becomes humid (its humidity rises). (Related reading: Overcurrent Protection with Resettable Fuses in Remote-Controlled Clothes Drying Racks)
 
 
This operating principle shows that a humidifier normally runs continuously, and the damp interior makes short circuits and the failures they cause very likely. Including a resettable fuse at the design stage is therefore the safer choice. After repeated testing, resettable fuses have become increasingly common as the overcurrent protection device in humidifier circuit design.
Resettable fuse in a humidifier
 
Humidifier
Resettable fuses are made of polymer materials and work according to Joule's law, Q = I^2 * R * T. The formula shows that the heat generated inside the device rises with the square of the current. While the humidifier runs normally, that heat is not enough to trip the fuse, so nuisance tripping does not occur. Once a short circuit appears, the current is several times its normal value, and a resettable fuse starts to protect as soon as the current through it reaches twice the normal operating current.
 
 
Once a resettable fuse has tripped, the power has to be switched off manually; after the fuse cools down it returns to the low-resistance state it had when it left the factory. If the current is not interrupted, a small residual current keeps flowing and holds the fuse at a high resistance, which safeguards the user. (Recommended reading: Is a Time-Lag Fuse Really Better Than a Fast-Acting Fuse?)
 
 
Because a resettable fuse has no polarity, it only has to be connected in series with the load circuit. Its mounting position is highly flexible and not limited by space, which is why more and more customers prefer resettable fuses.