What Is the Difference Between Two-Electrode and Three-Electrode Gas Discharge Tubes

A reader who goes by the screen name “Wandering Heart” emailed us to ask: what is the difference between two-electrode and three-electrode gas discharge tubes, and is there a large gap between them in application and performance? Today our editors take a look at how they differ.
 
 
Shenzhen Joincircuit Industrial Co., Ltd. answers: a gas discharge tube is a gap-type surge protective component. Its discharge electrodes are generally arranged as two or three electrodes, commonly called two-electrode and three-electrode gas discharge tubes. Their actual performance depends mainly on environmental parameters such as gas type, pressure and contamination level. (Related reading: 7.5*11.5 mm three-electrode surge arrester, 10 kA ceramic gas discharge tube, JTA37H series)
 
 
In terms of appearance, both leaded and leadless versions are available. The difference between a leadless two-electrode tube and a leadless three-electrode tube is obvious: the three-electrode tube has a clear dividing line in the middle, the two-electrode tube does not. Leaded versions differ just as clearly: a leaded two-electrode tube has two leads, a three-electrode tube has three.
 


 
Gas discharge tube

 
In terms of polarity, a two-electrode tube has no particular polarity: it can be mounted either way and works in differential or common mode. A three-electrode tube has one PE leg and is of common-mode type, with one electrode as the ground electrode; the three termination points connect lines a/b and ground, so that surge voltage is diverted to earth and the circuit is protected.
 
 
Differential mode, also called series mode, refers to the signal difference between two lines. A differential-mode signal is equal in amplitude and opposite in direction and does have a return path in the circuit; if a differential-mode signal is present on two lines, the signal is symmetric about the X axis. Common-mode noise, also called noise to ground, refers to the noise of each of the two lines with respect to ground. A common-mode signal is equal in amplitude and identical in direction, has no return path in the circuit, and acts on earth through distributed capacitance in the same phase. Put simply, the vector sum of a differential-mode signal on two conductors is zero, while the vector sum of a common-mode signal is reinforced.
 
 
In terms of surge suppression, for common-mode surges a single three-terminal GDT performs better than two two-terminal GDTs. The main reason is that the inside of a three-terminal gas discharge tube is connected: whichever end is triggered, the other end conducts quickly as well, preventing a common-mode surge from turning into a differential-mode one, and the operating times of the two paths are generally required to differ by no more than 200 ns.
 
 
In terms of breakdown behaviour, in a multi-electrode device only one electrode needs to break down; the remaining electrodes then conduct as well through the plasma produced by the discharge, even if they have not reached their breakdown voltage. Because of this characteristic, for equipment with an earth-return path, three- or even five-electrode devices are clearly the better choice in multi-port protection. Two-electrode devices are usually used to clamp the potential difference between lines.
 
 
That is the answer Shenzhen Joincircuit Industrial Co., Ltd. gives to our reader “Wandering Heart”. If you have the same question, or any other question about fuses, feel free to email us or leave a message for our editors on the Contact Us page, and we will reply as soon as we can. (Recommended reading: 10 kA three-electrode surge arrester with leads, 6*8.5 mm series gas discharge tube, JTA36H)