SMD fuses are a relatively high-technology newer product in the small fuse industry, and they divide into one-time SMD fuses and SMD resettable fuses. This article walks through the current ratings of SMD fuses.
1. Normal current: the current flowing through the circuit under normal operation. We usually keep a margin below the preset value and then apply this rule: the normal current must be lower than the rated current times the derating factor. (Related reading: Shenzhen 1206 Series One-Time Fast-Acting and Time-Lag SMD Fuses)
2. Breaking current: under UL requirements, an SMD fuse should open at twice its rated current in fast-acting terms. In most cases, though, to ensure reliable fusing we recommend a breaking current above 2.5 times the rated current. Fusing time also matters and must be judged against the manufacturer's time-current characteristics.
3. Short-circuit current: the maximum current value, which we call the short-circuit current. Every fuse has a required rated breaking capacity, and care must be taken never to apply a circuit current above that rating. If you fit a fuse with too small a breaking capacity, the fuse may rupture or start a fire.
4. Surge current: observe the current waveform (pulse current waveform) and the I2t value (joule integral) to calculate its energy. Different currents affect the fuse differently in amplitude and in the number of pulses. Compare the I2t of the surge with the rated I2t of the fuse to determine how many single-pulse surges it can withstand.
5. Open-circuit voltage: the open-circuit voltage should generally be chosen below the rated voltage. For example, in a circuit where the fuse is rated AC 100 V / DC 24 V, exceeding that level can strike an arc or crack the SMD fuse body.