深圳市集电通实业有限公司

电话 : 0755-8830-8258

邮编 : 518129

邮箱 : andyzheng@jdtfuse.com

网址 : http://www.joincircuit.com/

How to Select a Resettable Fuse: Key Points

Resettable fuse selection is a topic that draws constant attention. A well-chosen part lets a product run more efficiently and for longer, and keeps it safe and durable over its service life. This article sets out the points to watch when choosing a resettable fuse.
 
 
We know that a resettable fuse is an overcurrent protection device. It is made from a high-molecular organic polymer that is compounded with conductive particles and processed under high temperature and pressure through a special curing reaction. The PPTC is what we normally call a resettable fuse, and its job is overcurrent protection in a circuit. A resettable fuse is therefore specified by parameters such as voltage rating, current rating, holding current and trip time.
 
 
Selection means matching the fuse to the current, voltage and other parameters of the product, so the following points need attention.
 
 
First, determine the parameters. Start from the maximum ambient temperature of the protected circuit under normal operation, its normal and maximum operating current, the current at which protection must act, and the required trip time, then select the resettable fuse accordingly. (Related reading: Current Analysis of SMD Fuses)
 
 
Second, choose the form factor. Resettable fuses come in leaded and SMD versions, so pick leaded or SMD according to the characteristics of the protected circuit or product.
 
 
Third, determine the voltage rating. Choose a product series whose voltage rating is equal to or higher than the maximum operating voltage.
 
 
Fourth, determine the correct holding current. Check the maximum ambient temperature and the circuit operating current against the temperature derating curve of the resettable fuse, and pick the rating whose holding current fits.
 
 
Fifth, determine the trip time the product needs. Read the trip-time curve for the candidate part to confirm when protection will act.
 
 
Sixth, determine the size. Select the case size that suits the product.
 
 
For example, a circuit needs overcurrent protection. Its operating voltage is 48 V, its operating current is 450 mA and it works at 50 °C. Protection must act when the current reaches 1.4 A, and a 5 A current must be cleared within 2 seconds. Applying the six steps gives this selection. (Recommended reading: 250 V SMD Fuse, 2410 Package, Non-Resettable)
 
 
The 48 V operating voltage points to a series rated at 72 V. The holding-current versus temperature curves in the datasheet then narrow the choice to A72-065 and A72-075. The trip-time versus current curves show that both parts trip in about 1 second at 5 A, but the trip current of A72-065 is 1.3 A, which does not meet the requirement, so A72-075 is selected.
 
 
The example shows that following these six steps leads to a suitable part, even in a complex circuit. If anything is still unclear, leave a message on our contact page or ask our online sales staff, and we will give you a satisfactory answer.