Gas Discharge Tube Parameters and Design Cases

A customer with the screen name “Meng Xiaoxin” emailed us: I am a fuse enthusiast and have recently been studying gas discharge tubes, but some of the parameter questions are still unclear to me. Could you explain them? Design examples would be even better.
 
 
So here is our consolidated reply, covering the main parameters of gas discharge tubes and a few design examples, briefly explained below:
 
 
1) Response time is the interval from the moment the applied voltage exceeds the breakdown voltage to the moment breakdown occurs. GDT response time is typically in the microsecond range.
 
 
2) Power capacity is the maximum energy a gas discharge tube can withstand and dissipate. It is defined as the current the tube can withstand and dissipate under a fixed 8×20μs current waveform. (Related reading: GDT types and selection methods)
 
 
3) Capacitance is the capacitance measured between the two electrodes of the tube at a specific frequency of 1 MHz. GDT capacitance is very small, typically ≤1 pF.
 
 
4) DC breakdown voltage: when the applied voltage rises at a rate of 500 V/s, the voltage at which the tube sparks over is the breakdown voltage. GDTs are available in many different DC breakdown voltage ratings, and the value depends on factors such as the gas type and the distance between the electrodes.
 
 
5) Temperature range: the operating temperature range is typically -55°C to +125°C.
 
 
6) Insulation resistance is the tube resistance measured with an applied DC voltage of 50 V or 100 V; it is typically >10^10Ω. (Related knowledge: How to check a fuse when a switching power supply shuts down)
 

 
Surge protective tubes from Shenzhen Joincircuit Industrial Co., Ltd.

 
 
 
Typical design examples for gas discharge tubes are found mainly in telephones and fax machines, and in suppression circuits built from a gas discharge tube combined with a varistor. Both are briefly explained below:
 
 
1) Lightning protection for telephones, fax machines and other communication equipment
 
 
As shown in the figure, the features are low current, high continuous voltage, no leakage current and high reliability.
 
 
How gas discharge tubes work, how they are selected and how the design examples are analysed
 
 
2) A suppression circuit formed by a gas discharge tube in combination with a varistor
 
 
The figure below shows a surge suppression circuit built from a gas discharge tube and a varistor. A varistor has one fatal drawback: its leakage current is unstable, and a varistor of poor quality may heat up and burst after a period of use as the leakage current grows. To solve this problem, a gas discharge tube is connected in series with the varistor. In this series branch the gas discharge tube acts as a switch: when no transient overvoltage is present it isolates the varistor from the system, so that almost no leakage current flows through the varistor and the degradation of the varistor is effectively slowed. (Recommended reading: 10KA three-stage surge protective tube with leads, 6*8.5mm series gas discharge tube JTA36H)
 

 
Protection scheme using Joincircuit surge protective tubes
 
The above is our summary of the main parameters of gas discharge tubes and the related design examples. We hope it gives you a deeper understanding of gas discharge tubes. Customers and fellow enthusiasts are welcome to leave us a message: knowledge exchange and answers to product questions are all available on our Contact Us page.