Recently many customers have reported questions about testing SMD resettable fuses: whatever they measure, the data comes out wrong. Today we have put together the relevant background to answer these questions.
SMD resettable fuse
The test procedure is as follows:
1. Initial resistance Rimin: unpack the fuse, take it out and measure its internal resistance;
2. Soldering: solder the fuse onto a PCB by reflow soldering. The PCB carries lead wires so that electrical tests can be performed (as shown above);
3. Holding current Ihold test: use a DC constant-voltage constant-current source. Set the voltage to Vmax and the current to the holding current Ihold as specified in the datasheet, then energize for 15 minutes. (Related reading: SMD resettable fuse product information)
4. Tripping current Itrip test: use a DC constant-voltage constant-current source. Set the voltage to Vmax and the current to the tripping current Itrip as specified in the datasheet, then energize for 5 minutes;
5. R1max test: let the tripped fuse cool for 1 hour, then measure its internal resistance.
Acceptance criteria:
1. Testing is carried out at room temperature (25°C), free of light and heat radiation;
2. The initial resistance Rimin must be within the range given in the datasheet;
3. The fuse passes if it does not trip within 15 minutes at Ihold;
4. The fuse passes if it trips within 5 minutes at Itrip;
The above is a short test guide for SMD resettable fuses. If you have further questions, contact our online sales staff or talk directly to your account manager, and we will work out a more detailed solution for you.