TVS diodes and resettable fuses are very widely used together in everyday applications, so improper use of a TVS diode can affect the whole circuit. This article briefly explains how to use TVS diodes for reference.
1) A TVS diode is normally connected in parallel with the circuit it protects. To keep the current through the diode below the permitted peak pulse current IPP, a current-limiting element such as a resistor, a resettable fuse or an inductor should be connected in series with the line.
3) Choosing the peak pulse current IPP: when a TVS diode is used on its own, select the model according to the maximum surge current that may occur on the line. When it is used as a second-stage protector after a gas discharge tube, a 500 W to 600 W device is usually sufficient.
4) When protecting signal transmission circuits, pay close attention to the frequency or data rate of the signal. For high signal frequencies or data rates, choose a low-capacitance device: signal frequency (data rate) ≥ 10 MHz (Mb/s), Cj ≤ 60 pF; signal (data rate) ≥ 100 MHz (Mb/s), Cj ≤ 20 pF. If the low-capacitance series still cannot meet the requirement, connect the TVS diode into a bridge made up of high-speed diodes, as shown in the figure below. (Recommended reading: What is the difference between a TVS diode and a varistor)
TVS diode
The introduction above should give you a better understanding of how to use TVS diodes. If anything is still unclear, please leave a message for us on the Contact Us page and we will reply as soon as possible.