Combined Use of Fuses and Surge Protection Devices

In everyday life, lightning protection is a topic that never goes out of date. Whether in practical applications or in the classroom, knowledge about it is being passed on all the time. Today we will look at how fuses and surge protection devices are used together.
 
 
For electronic equipment that will be exposed to lightning interference or other transient disturbances in its working environment, lightning protection must be designed in at the design stage, and the protection level required depends on that environment. (Related reading: How ceramic gas discharge tubes protect circuits)
 
 
Lightning protection design mainly uses devices and assemblies such as gas discharge tubes, varistors, TVS diodes and commercial surge protection modules. The modules are usually fitted at the equipment ports. On the single-board power supply circuits inside the equipment, gas discharge tubes, varistors or TVS (transient voltage suppression) devices are mainly used.
Surge protection device
 
Gas discharge tube
 
 
On single-board power supply circuits, fuses are generally used for overcurrent and short-circuit protection, so that overcurrent caused by abnormal board operation cannot damage components or the complete equipment and cannot create a safety hazard. When surge protection devices and fuses are used on the same single-board supply circuit, two questions arise: how the fuse parameters should be selected to meet the circuit requirements, and whether the fuse and the surge protection device are matched.
 
 
Tests and analysis by engineers show that when a fuse and a surge protection device are used together in a single-board supply surge protection circuit, matching is an issue: if the parameters of the two are not coordinated, the protection capability of the circuit may be reduced. For example, when the surge withstand capability of the fuse is far below that of the surge protection device, the surge capability of the circuit depends entirely on the fuse, the protection device cannot give full play to its capability, and the overall protection effect is reduced. (Related knowledge: 10 kA ceramic gas discharge tube, leaded, 2-electrode, 2R075, JDT25H series)
 
 
When a fuse and a surge protection device are used together, the ideal combination is one in which the fuse does not reduce the surge withstand capability of the circuit while also protecting the surge protection device from damage. This requires the surge withstand capability of the fuse to be below that of the protection device, yet not too far below it; if it is far too low, the surge withstand capability of the circuit is impaired, and a surge the circuit could otherwise survive blows the fuse and stops operation.
 
 
The above is a brief introduction to the combined use of fuses and surge protection devices. If anything is unclear, please leave a message for us on the Contact Us page of our website and we will reply as soon as possible. (Recommended reading: Overcurrent protection for magnetic drive pumps with PPTC resettable fuses)