Normally, the way to cool a polymeric resettable fuse is to cut off the power to the protected equipment, which removes the fault current and lets the polymeric resettable fuse cool. While the fault is not cleared, the polymeric resettable fuse will not switch between the normal and the tripped state.
When a polymeric resettable fuse trips, its resistance moves from low to high, and in the high-resistance state a small residual fault current still flows. That small fault current is enough to keep the fuse in the high-resistance state. Only when the fault is cleared can the polymeric resettable fuse cool back to its low-resistance state. (Related reading: Resettable fuse protection in fingerprint door locks)
The longer a polymeric resettable fuse stays in the tripped state, the more likely its resistance will not return to its original value, so it may no longer meet its initial specification. How long each polymeric resettable fuse can remain tripped depends on the fault and its type. UL requires that a polymeric resettable fuse remain tripped at maximum voltage for 1000 hours without losing its PTC characteristics.
The time a polymeric resettable fuse needs to recover to the low-resistance state depends on many factors: the type of fuse; how it is mounted or fixed; the ambient temperature; and the cause of the trip and how long it lasted. Generally, although some recover within seconds, most polymeric resettable fuses recover within a few minutes. (Recommended reading: Resettable fuse protection in target-shooting machines)
The above is a brief introduction to the trip current characteristics and recovery behaviour of resettable fuses. If anything else is unclear, you are welcome to leave a message on the Contact Us page of our website and we will reply as soon as possible.