LED Switching Power Supply Faults (Part 2)

As a follow-up to the topic we left unfinished last time, Common Faults in LED Switching Power Supplies (Part 1), today we continue with more on the common faults of LED switching power supplies.
 
 
No DC output or unstable output voltage. In practical applications of LED switching power supplies another problem occurs frequently: no DC output, or unstable output voltage. If inspection shows that the fuse in the power supply is intact and yet there is no DC output at any stage under load, the cause is usually one of the following: an open circuit or short circuit inside the power supply; a fault in the overvoltage or overcurrent protection circuit; an auxiliary power supply fault; an oscillator circuit that is not working; excessive load on the power supply, and so on.
 
 
After using a multimeter to measure the secondary components and ruling out breakdown of the high-frequency rectifier diode and a short-circuited load, an output of zero at this point almost certainly means that the control circuit of the power supply has failed. A partial output voltage means that the preceding stage is working normally and the fault lies in the high-frequency rectifier and filter circuit. (Related reading: Innovative protection design for automotive electronic circuits)
 
 
The high-frequency filter circuit produces the DC output mainly through the rectifier diode and the low-voltage filter capacitor. Breakdown of the rectifier diode leaves this circuit with no output, while leakage in the filter capacitor causes faults such as unstable output voltage. A static measurement of the corresponding components with a multimeter will identify the damaged part.
 
 
Poor load capability. In practical applications of LED switching power supplies, poor load capability is also a very common fault, usually seen in older units or in ones that have run for a long time. The main causes of the drop in load capability are ageing of the internal components, unstable operation of the switching transistor and failure to dissipate heat in time. Once load capability drops, engineers should focus on checking whether the Zener diode heats up or leaks, and on damage to the rectifier diode and the high-voltage filter capacitor. (Recommended reading: How fuses protect automotive electronic devices)
 
 
That is our summary of the common faults of LED switching power supplies and how to deal with them. If you have any other questions, you are welcome to leave a message for us on the Contact Us page and we will reply as soon as possible.