How to Solve Varistor Aging Problems
How to Solve Varistor Aging Problems—A varistor is one of the most widely used electronic components today, and aging is its biggest drawback: it can seriously disturb the safe, normal operation of a system. So how can these problems be solved? Here is a brief explanation.
The first method is to connect the varistor in parallel with a ceramic discharge tube. This solves the degradation of varistor performance after a continuous high current and slows down the aging process. (Related reading: PPTC Resettable Fuse Manufacturers)
How to Solve Varistor Aging Problems—With this parallel arrangement the varistor starts to act before the discharge tube conducts: it clamps the transient overvoltage and discharges the large current. Once the discharge tube breaks down and conducts, it shares the current with the varistor in parallel, which relieves the current stress on the varistor and shortens the time it carries a large current, helping to slow the degradation of its performance.
In this parallel combination there is one point engineers must watch: if the reference voltage Uima of the varistor is chosen too low, the discharge tube may fail to conduct during the transient overvoltage, and the whole overvoltage energy has to be dissipated by the varistor alone, which is unfavorable to it.
How to Solve Varistor Aging Problems—The value of Uima must therefore be chosen somewhat higher than the DC discharge voltage of the discharge tube. It should be noted that this parallel circuit does not solve the follow current that the discharge tube may produce, so it is not suitable for protecting AC power systems.
Under normal operation a varistor in a circuit often has a fairly large parasitic capacitance. When it is used to protect an AC power system, it produces a considerable leakage current under normal operating conditions. (Related reading: What Is a Varistor and How Does It Work?)
How to Solve Varistor Aging Problems—For example, a varistor with a parasitic capacitance of 2 nF installed in a 220 V, 50 Hz AC power system can have a leakage current of up to 0.14 mA, and such a large leakage current often affects normal operation of the system. Once the varistor is connected in series with a ceramic gas discharge tube, however, the very small parasitic capacitance of the tube reduces the total capacitance of the series branch to a few microfarads.
In such a series branch the discharge tube acts as a switch. When no transient overvoltage is present, it isolates the varistor from the system so that almost no leakage current flows through the varistor. The reference voltage Uima can then be lowered without worrying that this will increase the leakage current, which slows the decline in varistor performance fairly effectively.
How to Solve Varistor Aging Problems—We hope that by now you have a general idea of how to solve varistor aging problems, and that the anti-aging measures described here will be of some help to design engineers working on circuit system design. If anything is still unclear, leave a message for us on the Contact Us page and we will reply as soon as possible. (Recommended reading: What Types of Varistors Are There? Functions and Working Principle of Varistors)