Resettable Fuse Voltage Rating and Selection

Resettable Fuse Voltage Rating and Selection —— What is the voltage rating of a resettable fuse? The voltage parameter of a resettable fuse is the highest working voltage it can withstand. If the actual working voltage is higher than the nominal rated voltage, the device may be broken down and burned out while in the protected state.
 
 
When engineers design a circuit protection scheme they inevitably need to understand the product circuit and the level of protection the product requires. Lightning surge protection, overvoltage protection, overcurrent protection and ESD protection are what electronics engineers encounter most often, and they also represent the largest protection demand in the electronics industry.
 
 
But customers also ask: resettable fuse is an overcurrent device, so when selecting an overcurrent protection device, is current the only thing to consider? Is resettable fuse selection really unrelated to voltage?
 
 
Shenzhen Joincircuit Industrial Co., Ltd. would like to point out that the following ten factors should be considered when selecting a resettable fuse: rated current; rated voltage; ambient temperature; voltage drop / cold resistance; fusing characteristics (overload capability, time/current characteristics); breaking capacity; melting energy value (I2t); endurance (service life); construction features; outline/dimensions and mounting style; and safety certification.
 
 
For safety reasons, a fuse must be selected with a rated voltage higher than the working voltage of the circuit, because a resettable fuse may trip falsely or even burn out when its withstand voltage is exceeded. The working voltage must not exceed either the rated voltage or the resettable fuse's withstand voltage; otherwise the device will not only fail to protect the circuit but will do the opposite and cause a safety accident.
 
 
Whether a fuse opens depends on the magnitude of the current flowing through it, not on the working voltage of the circuit. The rated voltage of a fuse is specified from the point of view of safe use: it is the maximum working voltage of the circuit in which the fuse may be installed while remaining in a safe operating state. (Recommended reading: Resettable Fuse Selection | Parameters | Part Numbers | How to Use)
 
 
This means a fuse may only be installed in a circuit whose working voltage is less than or equal to the fuse's rated voltage. Only then can the fuse work safely and effectively; otherwise, when the fuse opens, continuous arcing and voltage breakdown will occur and damage the circuit.
 
 