How Voltage Affects Resettable Fuse Selection

A few days ago we received several emails in the back office, all asking about specific part numbers for resettable fuse selection and related questions. One reader put it this way: voltage has little to do with resettable fuse selection, and what really matters is getting the current and resistance relationship right. Today we would like to explain briefly how to select a resettable fuse and what voltage has to do with it.
 
 
In practice, engineers who need to design a suitable circuit protection scheme for a product first have to understand the product and its protection level. Lightning surge protection, overvoltage protection, overcurrent protection and ESD protection are among the largest demands in the electronics industry, and within overcurrent protection the resettable fuse is the most widely used device.
 
 
What Shenzhen Joincircuit Industrial Co., Ltd. wants to make clear here is that resettable fuse selection should take the following ten factors into account: rated current; rated voltage; ambient temperature; voltage drop / cold resistance; fusing characteristics (overload capability, time/current characteristics); breaking capacity; melting heat energy (I2t); durability (service life); construction features; shape/size and mounting style; safety certification. All of these factors are closely tied to voltage, and engineers choose the appropriate voltage, current and other parameter values according to the requirements of the product. (Related reading: Key Points in Resettable Fuse Selection, How to Choose a Resettable Fuse)
resettable fuse
fuse
 
 
A conventional fuse provides overcurrent protection only once and has to be replaced after it blows, whereas a resettable fuse combines overcurrent and overtemperature protection with automatic recovery. The resettable fuse selection tips compiled by Joincircuit are as follows: choose a suitable part number according to the maximum circuit operating voltage V, the normal operating current I, the fault current If and the maximum ambient temperature TM. At the maximum ambient temperature TM the following must be satisfied: (1) IH(TM) slightly greater than I; (2) IT(TM) ≤ If ≤ Imax; (3) Vmax ≥ V.
 
 
The rated voltage of a fuse is specified from the point of view of using the fuse safely: it is the highest operating voltage of the circuit in which the fuse can be installed and still work safely. This means that a fuse may only be installed in a circuit whose operating voltage is less than or equal to the rated voltage of the fuse. Only then can the fuse work safely and effectively; otherwise, when the fuse element melts, continuous arcing and breakdown caused by the circuit voltage will occur and endanger the circuit.
 
 
Joincircuit therefore recommends that, for safety, the circuit voltage must stay below the rated voltage of the fuse selected. Many people overlook this parameter in practical applications, assuming that everything is settled once the fusing current has been fixed. In fact it is better to pay close attention to it, and resettable fuse selection is far more forgiving in this respect. (Recommended reading: Applications of Resettable Fuses in Electronic Equipment)
 
 
This is mainly a matter of the characteristics of the resettable fuse itself. When the voltage exceeds its withstand rating, a resettable fuse may trip spuriously or be burned out. Both the rated voltage and the withstand voltage must therefore be respected; otherwise the device will not only fail to provide protection but may also cause a safety incident.