Selection Principles for Resettable Fuses

In an earlier article we briefly introduced how a resettable fuse works, which is determined by the structure of the fuse itself: the carbon-black particles separate and rejoin to conduct current, raising and lowering the resistance of the device. Today we will explain the principles for selecting a resettable fuse.
 
 
There are six main selection principles for resettable fuses.
 
 
1. Determine the following circuit parameters: a. maximum ambient operating temperature; b. normal operating current; c. maximum operating voltage (Umax); d. maximum fault current (Imax).
 
 
2. Choose a resettable fuse that suits the maximum ambient temperature and the normal operating current of the circuit: use the temperature derating table {operating current (A) at ambient temperature (°C)} and select the temperature that best matches the maximum ambient temperature of the circuit. Read down that column for a value equal to or greater than the normal operating current of the circuit.
 
 
3. Compare the maximum electrical ratings of the selected device with the maximum operating voltage and fault current of the circuit: use the electrical characteristics table to verify that the device chosen in step 2 will see the maximum operating voltage and fault current of the circuit. Check the maximum operating voltage and maximum fault current of the device, and make sure that Umax and Imax are greater than or equal to the maximum operating voltage and fault current of the circuit. (Related reading: Resettable fuse holding current explained)
 
 
4. Determine the trip time: the trip time is the amount of time the device takes to switch to the high-resistance state when a fault current appears in the equipment. To provide the protection intended, it is important to know the operating time of the resettable fuse. If the device trips too fast, abnormal or harmful tripping will occur; if it trips too slowly, the protected components may be damaged before the device switches to the high-resistance state.
 
 
Use the typical trip-time curve at 25°C to judge whether the trip time of the resettable fuse is too fast or too slow for the circuit. If it is, return to step 2 and select an alternative device.
 
 
5. Verify the ambient operating temperature: use the ambient temperature versus current derating table to make sure that the minimum and maximum ambient temperatures of the application fall within the operating temperature range of the resettable fuse. Most resettable fuses operate over a range of -40°C to 85°C.
 
 
6. Verify the dimensions of the resettable fuse: use the dimensions table to compare the resettable fuse you have selected with the space available in the application.
 
 
That covers the selection principles for resettable fuses. If anything remains unclear, please leave us a message on the Contact Us page and we will reply as soon as possible.