Selecting an SMD Resettable Fuse

Selecting an SMD resettable fuse —— electronic components are becoming ever smaller as component technology advances, so SMD resettable fuses are widely used. Because of differences in construction, an SMD resettable fuse offers advantages over a leaded resettable fuse. Many people still have misconceptions about SMD resettable fuse selection, so here is a brief explanation.
 
 
An SMD resettable fuse is specified mainly by its operating voltage, operating current and fault current. Selection is based on the maximum line voltage V, the normal operating current I, the fault current If and the maximum ambient temperature TM, and at TM the following must hold: (1) IH(TM) slightly greater than I; (2) IT(TM) ≤ If ≤ Imax; (3) Vmax ≥ V.
 
 
The line voltage and current referred to in SMD resettable fuse selection are DC values or AC RMS values. A resettable fuse is normally connected in series at the front end of the circuit to be protected. Used in place of a current fuse it removes the need for frequent replacement. (Related knowledge: Resettable fuse specifications, models and parameters)
 
 
The following points deserve particular attention when selecting an SMD resettable fuse, so that the circuit stays safe.
 
 
Holding current: the normal current of the circuit must be established first, in order to choose the corresponding SMD resettable fuse.
 
 
Tripping current: when selecting a part for the circuit to be protected, the tripping current of the SMD fuse must be less than or equal to the current at which the protected circuit needs protection.
 
 
Tripping time: some protected circuits must be protected within a given time at a given current, so it is necessary to check whether the protection time of the fuse meets that requirement.
 
 
Operating ambient temperature: a resettable fuse in a circuit is subject to a temperature derating that depends on the operating ambient temperature, and an SMD fuse is no exception. The appropriate derating must therefore be applied when selecting an SMD resettable fuse, so that the part is used below its rating.
 
 
Product size: SMD fuses are generally used in highly integrated products, so selection must take account of whether the package can be fitted properly on the circuit to be protected.
 
 
The above covers SMD resettable fuse selection. If anything remains unclear, leave us a message on the Contact Us page and we will reply as soon as possible. (Recommended reading: Fuse Supplier in Guangdong)