A reader with the screen name "I am a toy manufacturer" left a message in the backend: one of our products now uses resettable fuse PPTC and shows yellowing and smoke, but when we tested it with high voltage and high current this never happened, that is, the fault condition cannot be reproduced.
PPTC is 120 mA, maximum working voltage 60 V, protection current 180 mA; in practice the working circuit is 60 mA at a working voltage of 48 V; in a batch of 240 pieces, more than 80 have this problem. We do not know what is causing it.
A specialist from Shenzhen Joincircuit Industrial Co., Ltd. replied: this situation is generally caused by a fault in the working circuit, and it is also related to the application environment of the product. (Related reading: What Causes a Resettable Fuse to Self-Ignite or Burn Out)
As we know, the PPTC body is a polymer material mixed with a particulate carbon chain, and conduction is formed by the connection of the carbon chain. Under normal working conditions the device temperature stays in the normal working range, the carbon chain stays connected and the circuit keeps conducting. Under abnormal high current the large current flowing through the carbon chain generates heat, the polymer expands with heat and the carbon chain is pushed apart, so the internal resistance of the device increases or the device opens and the circuit is protected. When the temperature returns to normal, the polymer contracts, the carbon chain reconnects and the circuit works normally again.
PPTC manufacturers generally provide a HOLD current and a TRIP current. The HOLD current is the maximum current at which normal operation is guaranteed, and the TRIP current is the minimum current at which protection is guaranteed to operate. The gap between the HOLD and TRIP currents is an indeterminate state: the device may work normally, or it may trip.
The yellow smoke from a resettable fuse is most likely caused by the power supply being applied directly across the two terminals of the PTC, which produces instantaneous high heat and causes the polymer to overheat and degrade; this process is irreversible. (Recommended reading: How Fuses Work in Household Circuits)
Therefore the specific cause still has to be analysed together with the actual application of the product. The above are the relevant answers we have briefly compiled for you. If anything is still unclear, you are welcome to leave a message for us on the Contact Us page and we will reply as soon as possible.