Shenzhen JDT Fuse Industrial Co.,Ltd

Phone : 0755-8830-8258

Postcode : 518129

E-Mail : andyzheng@jdtfuse.com

URL : http://www.joincircuit.com/

Fast-Acting vs Time-Lag Fuses: A Comparison

In the fuse industry we often hear the terms fast-acting and time-lag, yet they can be confusing in practice. So what exactly is the difference between fast-acting and time-lag fuses? This article explains it. (Related reading: Leaded 3.6 × 10 mm Glass Tubular Time-Lag / Fast-Acting Fuses)
 
 
First, not every fuse comes in fast-acting and time-lag versions. Normally only one-time fuses and ceramic tubular fuses are divided in this way, because the choice depends mainly on whether the fuse must withstand transient pulses. The key difference between fast-acting and time-lag fuses lies in their ability to withstand transient pulse currents: a time-lag fuse rides through the inrush current generated at switch-on and switch-off without operating, so the equipment keeps running normally. Time-lag fuses are therefore also called surge-resistant fuses.
 
 
Technically, a time-lag fuse has a higher melting I2t than a fast-acting fuse, which means the time-lag fuse has better breaking capacity and better surge withstand. (Tip: What Is Breaking Capacity)
 
 
Because the I2t of a time-lag fuse is larger than that of a fast-acting fuse of the same rating, the melting time of the time-lag fuse is longer. Does that mean protection performance is worse? The answer is no, certainly not. When a fault occurs in the circuit, the overcurrent does not disappear by itself; the energy of the sustained overcurrent far exceeds the I2t of the fuse, so any fuse will melt. The difference in melting time between fast-acting and time-lag fuses then no longer matters, and it only affects protection performance where a rather sensitive component in the protected circuit needs protection.
 
 
Because fast-acting and time-lag fuses differ as described above, they are used in different circuits. Capacitive or inductive circuits (inrush at switch-on and switch-off) and power supply inputs and outputs are best protected with time-lag fuses; purely resistive circuits (little or no inrush) and circuits that must protect sensitive, expensive devices such as ICs require fast-acting fuses. Apart from circuits protecting ICs, most applications that use fast-acting fuses can switch to time-lag fuses to improve pulse withstand. Conversely, fitting a fast-acting fuse where a time-lag fuse is required will cause the fuse to open as soon as the equipment is switched on, and it will not work properly.
 
 
So when selecting a fuse, give full consideration to the environment in which it will be used and to the equipment it protects. Note also that time-lag fuses generally cost considerably more than fast-acting fuses, so cost may favour fast-acting fuses; either choice can be made according to the customer's requirements. (Recommended reading: How Rated Current Relates to Melting Current in a Fuse)