How to Select LED Overcurrent Protection Devices for Different Current Input Types
Overcurrent protection devices are usually selected according to the rated current and rated voltage of the product in operation, yet different current input types affect the parameter values in an unpredictable way. To help you pick the right overcurrent protection device more accurately, this article looks at how to select LED overcurrent protection devices for different current input types.
First, a power supply generally takes either a DC or an AC input. The differences in device selection between the two are set out below:
1. For a fuse at the DC-in position, the temperature derating factor has a very large effect and deserves particular attention. High-power LEDs generate a lot of heat, which raises the temperature inside the LED cup; with a large derating factor the current rating selected becomes larger, and at the same operating current a fuse with a larger current rating protects less. (Related reading: Overcurrent Protection of Explosion-Proof Lamps with Resettable PPTC Fuses)
The DC-in position also sees a fairly large start-up pulse current, because the downstream circuitry uses capacitive filtering. The fuse chosen here must therefore take the pulse conditions strictly into account; otherwise the fuse may be blown by the start-up pulse and will hardly survive repeated surge and power-up tests. A product with strong pulse withstand capability is needed at this position.
For fuse selection at the output, both the temperature derating factor and the opening speed of the fuse must be considered. The current here fluctuates little, but when a fault occurs or a component fails the circuit has to be cut to protect the LED string downstream, so a fast-acting fuse with a small derating factor should be used at this position.
As the analysis above shows, for both of these two applications there are plenty of low-voltage SMD fuses to choose from on the market. Shenzhen Joincircuit Industrial Co., Ltd., for instance, offers sizes from 0402 to 1206 with current ratings from 0.5 A to 30 A, including fast-acting, ultra-fast-acting, high-pulse-withstand and time-lag versions in a wide range of specifications and characteristics.
2. For the AC-in position of AC-input LED lighting, the voltage rating has to reach 250 VAC to suit the size and position constraints of the product. Joincircuit's JFC2410 series SMD fuses measure only 6.1 mm * 2.5 mm * 2.2 mm, yet this small package withstands 250 VAC, and it also offers high consistency, low internal resistance and strong pulse withstand capability, making it the preferred choice of customers.
Finally, some engineers assume that a fuse has no polarity and can be connected anywhere in the circuit, and that it will protect the circuit whenever an overcurrent occurs. That is not correct. To share some experience: a fuse has to be placed on a line that has a potential difference with respect to ground. A fuse used on the ground line can break the circuit as well, but once it opens a potential difference still exists between the lamp and earth, and if the internal circuit develops a short circuit, danger can easily follow. In countries where sockets can be inserted either way, such as Germany or China, it is therefore best from a safety point of view to fit a fuse on circuits that can be reversed.
The points above summarise fuse selection for LEDs on different current input sides. If anything remains unclear, please consult Joincircuit's online sales team or leave a message for us on the Contact Us page, and we will reply as soon as possible. (Recommended reading: Overcurrent Protection of Multi-Branch Power Supplies with Resettable PPTC Fuses)