Fuse vs. Fuse Tube: Types and How to Select

A fuse is also commonly called a fuse tube, and there is little real difference between the two words. In most cases they mean the same thing, and people simply use whichever they are used to. Some engineers do reserve “fuse tube” for the glass or ceramic tubular types, though, so the intended meaning depends on the context. Below is a short guide to selecting a fuse (fuse tube).
 
 
a) Determine the safety mark. Based on the markets in which the product will be sold, choose the safety certification mark and the safety standard for the fuse (UL or IEC).
 
 
b) Determine the dimensions. Based on the mounting space available and on the safety mark and standard chosen above, decide the physical size of the fuse. (Related reading: How Fuses Have Evolved and What They Must Meet)
 
 
c) Determine the type. Select the type according to the current characteristics of the circuit being protected. Where that current is constant, for example, choose a fast-acting type.
Fuse
 
 
d) Determine the rated voltage. The rated voltage follows from the input voltage of the protected circuit and from the way it is used. With a 220 V input, select a fuse rated at 220 V or above – 250 V, 300 V or 350 V, for instance. Going much higher only adds cost.
 
 
e) Determine the minimum rated current. Take the steady-state operating current of the protected circuit together with the applicable derating factors to arrive at a preliminary rated current. With a steady-state current of 1 A, a UL time-lag fuse and an ambient temperature of about 80 °C, the minimum rated current is 1 A × 1.25 ÷ 0.5 = 2.5 A.
 
 
f) Determine the minimum I²T of the fuse. Match it to the surge I²T of the protected circuit. If a surge I²T of 1 A²s has to be withstood more than 100,000 times, the I²T of the fuse must be greater than 1 ÷ 0.2 = 5 A²s.(Related reading: The Theory behind Fuse Elements)
 
 
 
g) Determine the rated current of the fuse. With the minimum rated current and the minimum I²T established, look up the corresponding ratings in the catalogue and take the first standard rating that is both above the minimum current and above the minimum I²T.
 
 
For the minimum values above: (1) if the I²T of the 2.5 A rating is 4.3 A²s and that of the 3 A rating is 5.4 A²s, select 3 A; (2) if the I²T of the 2 A rating is 5.3 A²s and that of the 2.5 A rating is 7.6 A²s, select 2.5 A.
 
 
Shenzhen Joincircuit Industrial Co., Ltd. has 15 years of experience in the fuse industry. We keep building on our strengths in the field – seizing opportunities, opening new markets and expanding capacity – as we work towards our goal of a first-class company with a first-class image, first-class people and first-class results. Management and production follow 3C quality standards, and everything we do is centred on the customer. Visitors from every sector are warmly welcome. (Recommended reading: Why Fuses Blow: The Causes of Fuse Failure)