Shenzhen JDT Fuse Industrial Co.,Ltd

Phone : 0755-8830-8258

Postcode : 518129

E-Mail : andyzheng@jdtfuse.com

URL : http://www.joincircuit.com/

How Can PPTC Resettable Fuses Fail?

A reader named “Furlong” emailed us to ask: the resettable fuse is an electronic component we use all the time, but careless storage can still make one fail. What are the situations in which it can fail?
 
 
A specialist at Shenzhen Joincircuit Industrial Co., Ltd. replies: the number of trips a resettable fuse survives depends on the recovery time allowed after each trip, and the longer that time, the more cycles it withstands. The standard PPTC test condition allows 120 seconds of recovery after each trip, and performance is guaranteed after 1,000 trip cycles. (Related reading: Application issues with resettable fuses in tablet computers)
 
 
The common failure situations for a PPTC resettable fuse are therefore numerous trips, a trip sustained over a long period, a voltage above the rated operating voltage Vmax, and a fault current above the rated trip current Imax. Other failure modes are far less likely.
 
 
In short, a PPTC resettable fuse usually fails through a drop in its performance parameters or by going open circuit. (Recommended reading: What causes a resettable fuse to self-ignite or burn out)
 
 
That covers how PPTC resettable fuses can fail. If anything remains unclear, leave a message for Joincircuit on the Contact Us page and we will reply as soon as possible.