What Are the Failure Modes of a Varistor

Varistors and resettable fuses are widely used in practical designs, and how a varistor fails is a subject many engineers watch closely. Today we take a brief look at how a varistor fails and what its failure modes actually look like.
 
 
Specialists at Shenzhen Joincircuit Industrial Co., Ltd. explain that a varistor fails in three ways:
 
 
The first is degradation: leakage current grows and the varistor voltage falls markedly, until it reaches zero.
 
 
The second is rupture. If the surge energy behind an overvoltage is too great and exceeds the withstand capability of the selected varistor, the ceramic body will crack while the varistor is suppressing the overvoltage. (Related reading: How to Select a Varistor (VDR) and What to Watch For)
 
 
The third is punch-through. When the overvoltage peak is very high, most varistor failures take the form of degradation followed by punch-through (a short circuit). The remedy is to connect a suitable circuit breaker or fuse in series with the varistor, so that a short circuit does not lead to an accident.
 
 
In summary, when the clamping voltage of a varistor drops while it absorbs a surge, its operating current rises until the device burns out. When the body ruptures (the encapsulation cracks and the leads separate from the ceramic body), the circuit opens and protection is lost. When the disc shorts, the device burns out. Excess humidity in the operating environment degrades the varistor (lowering the clamping voltage), again driving the current high enough to burn it out or short it; the same happens when the applied voltage exceeds the rated operating voltage.
 
 
Failures in which a varistor catches fire fall broadly into two types: ageing failure and transient overvoltage damage. (Related knowledge: A Guide to Common Thermistor Parameters)
 
 
1) Ageing failure. The low-resistance linearisation of the ceramic body gradually worsens, leakage current climbs steeply and concentrates in weak spots, the material there melts and a short-circuit hole of roughly 1 kOhm is formed; the supply then keeps driving a large current into the short, producing intense heat and ignition. Such accidents can usually be avoided with a thermal link in series with the varistor. The link must be well coupled thermally to the body: it must not open when the maximum surge current flows, but it must open once the temperature exceeds the upper limit of the body's operating temperature. Research shows that varistors with manufacturing defects are prone to early failure, and repeated electrical surges of moderate strength also accelerate ageing and bring ageing failure forward.
 
 
2) Transient overvoltage damage. A strong transient overvoltage punches a hole through the body, letting a much larger current flow, with intense heat and ignition. The whole process takes place in such a short time that the thermal link built into the body has no chance to melt. In three-phase supply protection, varistors connected between the N and PE lines have a comparatively high probability of burning out and catching fire, and most such cases belong to this category. Countermeasures therefore centre on preventing ignition after the varistor has been damaged. Some varistor application notes recommend protecting the varistor with a current fuse in series.
 
 
That is a brief summary of varistor failure modes. If anything is still unclear, leave a message for us on the Contact Us page of our website and we will get back to you as soon as possible. (Recommended reading: What Is the Difference Between a TVS Diode and a Varistor)