A gas discharge tube is a switching-type protective device that works by gas discharge, and it is used practically wherever overvoltage occurs. To use one well, you have to pick the right device for the actual circuit by reference to its ratings; otherwise the result is worse than no protection at all. The following points need attention during design and use:
1. Nominal DC breakdown voltage: it must not be lower than 1.5 times the working voltage. Where the current capacity is large enough, a lower DC breakdown voltage can be chosen so that protection takes effect quickly when a surge arrives.
3. Consider the effect of residual voltage on the downstream circuit. A GDT cannot be used on a power supply on its own: it has a follow-on (arc) voltage of roughly 30 V or less, and if the working voltage exceeds that value the GDT will stay conducting. It must be used together with a varistor; see the standard circuit.
4. Current capacity: the surge current rating is set by the required standard level.