Advantages of Lightning Protection Components

In everyday life, lightning protection components are indispensable safety devices for outdoor installations. Many people only know that a protector guards against lightning, and overlook the considerable advantages of the devices themselves. Today we will briefly go through the advantages of lightning protection components.
 
 
During normal operation the switching element is off; when a lightning surge arrives the switching element conducts and diverts the surge current to earth, protecting electronic equipment from surge damage. Switching-element types include ceramic gas discharge tubes, glass discharge tubes (high-energy discharge tubes) and semiconductor overvoltage protectors (semiconductor discharge tubes, solid-state discharge tubes).
 
 
Lightning protection components offer the following eight main advantages:
 
 
① Before breakdown (conduction) they behave as an open circuit with very high resistance and almost no leakage current; (Related reading: Precautions for Using Lightning Protection Components)
 
 
② After breakdown (conduction) they behave as a short circuit, carrying very large currents with a very small voltage drop;
 
 
③ Large impulse current capacity (peak current): for ceramic GDTs the common 8/20 µs peak currents are 5 kA, 10 kA and 20 kA (larger types exceed 100 kA), and the 10/1000 µs peak current lies between tens and hundreds of amperes; glass discharge tubes offer 8/20 µs peak currents of 500 A, 1 kA and 3 kA; semiconductor overvoltage protectors have 10/1000 µs peak currents between tens and about one hundred amperes.
 
 
④ Apart from some semiconductor overvoltage protectors, all of them have bidirectional symmetrical characteristics.
 
 
⑤ Ceramic GDTs and glass discharge tubes have very low capacitance, below 3 pF.
 
 
⑥ Glass discharge tubes and semiconductor overvoltage protectors respond very quickly, in the nanosecond range.
 
 
⑦ Glass discharge tubes can be built with very high breakdown voltages, up to 5 kV. (Related reading: Combined Use of Fuses and Lightning Protection Devices)
 
 
⑧ Semiconductor overvoltage protectors provide very accurate breakdown voltages.
 
 
These are the advantages of lightning protection components summarised above. If anything is still unclear, please leave a message on our Contact Us page and we will reply as soon as possible.