Analysis of Fuse Failures in Color TVs

Times move on and society develops: from the big screens of the past to the black-and-white sets in every household, and finally to color television. As after-dinner entertainment, the color TV has been a loyal "companion" all along, yet in everyday use you occasionally run into a few fuse failure problems. Today we will walk through them briefly.
 
 
The switch-mode power supply is a very important circuit in a color TV, and it provides every operating voltage for the whole set. Working at high current and high voltage, it is a circuit that fails easily, so color TVs always include an AC glass tubular fuse in the supply circuit. Once the load current becomes too large or an accident occurs, the fuse blows and opens the circuit almost immediately, protecting the rest of the set.
 
 
To check whether a fuse has blown you can normally use the resistance range of a multimeter: an infinite reading means the fuse is open. You can also inspect it directly, since a grayish-white smoky look inside the glass tube, or a blackened tube wall, also shows that the fuse has blown. Once the fuse is open you will not hear the degaussing noise when the set is switched on, nor the "click-click" of the relay pulling in and dropping out. The fuse element inside a color TV fuse is made of a material to a special specification, so an ordinary tubular fuse should not be used as a substitute. In an emergency, however, an ordinary tubular fuse rated at 1.5 to 2.5 times the capacity of the original may be used until the correct part is obtained. (Related: resettable fuse specifications)
Color television
Color television
 
A blown fuse shows that a short-circuit fault has appeared in the circuit, and there are usually three patterns. First, when the fuse carries 1.5 to 2.5 times its rated current, the fuse element melts slowly and takes a very distinctive shape: it usually breaks in the middle, the parted ends are ball-shaped because of surface tension, and the gap between them is very short, that is, only a short section in the middle of the element is lost.
 
 
Second, when the current rises to 5 to 8 times the rated value, the clearing time falls to about one second and the element no longer breaks at a single point but at several: the large current heats the element rapidly, several weak spots melt at once, and the inside of the glass tube turns grayish-white and smoky.
 
 
Third, when the current is larger still, the inner wall of the fuse tube is already blackened and the element is gone altogether, because the heavy current has vaporized it and deposited it on the glass.
 
 
When analyzing a blown fuse you can judge from the pattern whether the circuit has a severe short circuit or whether the fuse simply blew by chance, for example because the supply voltage rose unexpectedly or because the fuse fitted after a repair was rated too low. So when you find a blown fuse, first check whether it shows the first pattern or the second and third. (Further reading: A brief look at the market outlook for SMD fuses)
 
 
If it is the first pattern (which is not common, being caused by a slight overcurrent or overvoltage), fit another tubular fuse of the same rating and try again. If all is well, the failure was incidental, usually caused by a rise in the AC supply; in remote rural and mountain areas the mains voltage can climb to around 280 V at night, which is beyond the stabilization range of a color TV power supply.
 
 
If it is the second or third pattern, do not switch the set on again, or the fault will spread. Some component in the circuit has certainly broken down and shorted, and the circuit must be serviced. When the fuse in a switch-mode supply blows, the set usually shows the classic triple symptom: no picture, no sound and no light. During servicing it is best to disconnect all loads and connect a dummy load (a 60 W or 100 W incandescent lamp) between the +B output and ground, which prevents damage to load components while you work.
 
 
The usual reasons why a fuse blows as soon as the set is switched on are: a short in the high-frequency filter network on the 220 V input path (for example a capacitor between line and neutral breaking down, or a short between primary and secondary of the common-mode filter); a severe short in the rectifier and filter circuit (for example a rectifier diode, or the capacitor connected across it, breaking down); serious leakage or breakdown of the +B filter capacitor; failure of the switching oscillator transistor and of the switching transistor (or of the switching transistor inside the thick-film switch-mode IC); and short circuits in the degaussing coil or degaussing resistor, as well as breakdown shorts in other components.
 
 
The above is a brief explanation of some of the causes of fuse failures in color TVs. If anything is still unclear, leave a message for us on the Contact Us page and we will reply as soon as possible. (Recommended reading: How resettable fuses are applied in security systems)