How Resettable Fuses and Fuses Break Current: Principles Explained
Resettable Fuses and Fuses: Breaking Principle Explained — both fuses and resettable fuses provide overcurrent circuit protection, and both work by responding to the heat generated by the current flowing through the circuit.
A fuse interrupts current by blowing, whereas a resettable fuse limits the current by switching from a low-resistance state to a high-resistance state. A clear understanding of how the two devices differ makes it far easier to choose the best circuit protection solution. (Related reading: Overcurrent Protection with Resettable Fuses)
Resettable Fuses and Fuses: Breaking Principle Explained: the biggest difference is that a resettable fuse recovers by itself. After an overload, the usual recovery step is to remove power so that the device cools down. The two products also differ in several other operating characteristics. The terms used for resettable fuses are usually similar to those used for fuses, but not identical. Leakage current and interrupt rating are two such parameters.
Leakage current: under overload, a resettable fuse switches from a low-resistance state to a high-resistance state, a transition commonly called “tripping”. Current is limited to some leakage level, which is how protection is achieved. Leakage current can rise from about one hundred milliamps at rated voltage to several hundred milliamps at lower voltages. With a fuse, however, an overload blows the element and interrupts the current completely, so the leakage current of the opened circuit is “0”.
Interrupt current: the maximum short-circuit current a resettable fuse is rated to withstand at rated voltage. This fault current is the maximum the device can take, and a resettable fuse generally does not actually interrupt the current (see “leakage current”); the standard short-circuit rating of a resettable fuse is 40 A. A fuse, by contrast, really does interrupt the current when it responds to an overload. At rated voltage the rated interrupt current covers a wide range, from several hundred amps to 10,000 amps. (Related knowledge: Resettable Fuse Product Overview)
Rated voltage: a conventional resettable fuse is rated at no more than 60 V, while a fuse can be rated up to 600 V. Rated current: a resettable fuse carries a rated operating current of up to 11 A, whereas the maximum rated operating current of a fuse can exceed 20 A.
Rated temperature: the usual upper temperature limit of a resettable fuse is 85°, while the maximum operating temperature of a fuse is 125°C. Both devices must be derated when operated above 20 °C, and representative curves are given in the literature.
Agency approvals: resettable fuses are recognized under the Underwriters Laboratories, Inc. component program and comply with UL standard 1434 for thermistors. The device has also been accepted under the CSA Component Acceptance Program. With TUV and VDE approvals, resettable fuses can also be said to meet IEC standard 730-1 (automatic electrical controls). Fuse approvals include the Underwriters Laboratories component program and the CSA Component Acceptance Program. In addition, many fuses can be supplied with full “Listing” to the newer fuse supplementary standard UL 248-14.
Resistance: product specifications show that, at comparable ratings, the resistance of a resettable fuse is twice that of a fuse (sometimes higher). Time-current characteristics: comparing the time-current curves of resettable fuses and fuses shows that the response time of a resettable fuse is comparable to the time delay of a Slo-Blo? fuse. (Recommended reading: Shenzhen SMD Resettable Fuse Wholesale)
The above is a brief explanation of how resettable fuses and fuses break current. If anything remains unclear, please leave a message for us on the Contact Us page and we will reply as soon as possible.