Installation and Use Notes for Leakage Circuit Breakers

Installation and Use Notes for Earth Leakage Circuit Breakers——Contact with electrical appliances is unavoidable in everyday life, and for the sake of safety many people have started to use earth leakage protection devices. Here is a brief introduction to the points to note when installing and using an earth leakage circuit breaker.
 
 
To ensure that an earth leakage circuit breaker really provides protection against electric shock and leakage, the following points should be observed during installation and use:
 
 
(1) Before installation and use, read the product manual carefully, understand the performance and installation requirements of the product, and master the correct wiring method. (Related reading: What is the difference between a fuse and a thermal relay)
 
 
(2) The breaker should be installed in a place free of corrosive and explosive gases, free of vibration, and protected from rain and snow.
 
 
(3) The incoming supply line must be connected at the top of the breaker, that is, the side marked “POWER” on the housing; the outgoing line must be connected at the bottom, the side marked “LOAD”. After installation, the handle at position “O” means “OFF” and the circuit is open; at position “I” it means “ON” and the circuit is closed.
 
 
(4) Where a leakage circuit breaker is installed on a single-phase household supply, the neutral conductor inside the protected circuit must not be earthed at a second point, and household appliances must not use the neutral conductor as their protective earth; otherwise the breaker will not work properly.
 
 
(5) If the household appliances were already protectively earthed, the earth wire need not be removed. Keeping it only increases the reliability of the breaker tripping and is better for personal safety. (Related reading: Applications of fuses in fire alarm and security systems)
 
 
(6) Once the breaker has been installed and checked, an energised test can be carried out. Move the handle to the ON position so that the circuit is closed and press the test button (this simulates a person receiving an electric shock). If the trip unit operates immediately, the handle returns to the OFF position and the supply is cut off, the breaker is functioning correctly; close the handle again, restore the supply, and it is ready for use.
 
 
(7) After the breaker has been put into service, inspect it as described in the manual (generally once a month). With the circuit energised, press the test button and check that it trips reliably. If the switch does not trip, the breaker is faulty: stop using it and have it repaired.
 
 
(8) If the breaker trips in service, first look at the white leakage indicator button (as on type DZL18-20). If the button has popped out, there is leakage in the electrical wiring or in a household appliance, or an electric shock may have occurred; find the cause of the fault, clear it, then press the indicator button back to reset it before closing the switch again. If the indicator button has not popped out, the fault is an overload (where the breaker also provides overload protection).
 
 
(9) Even with a leakage circuit breaker fitted, electrical safety still deserves attention. Do not imagine that a breaker lets you relax your guard, and do not use a leakage circuit breaker as a substitute for all other safety measures, because a breaker too can lose its protective function. (Recommended reading:
Shenzhen SMD resettable fuse wholesale)
 
 
Installation and Use Notes for Earth Leakage Circuit Breakers——That is a brief outline of the points to note when installing and using an earth leakage circuit breaker. If you have any questions or suggestions, please leave a message for us on the Contact Us page of our website and we will reply as soon as possible.