Shenzhen JDT Fuse Industrial Co.,Ltd

Phone : 0755-8830-8258

Postcode : 518129

E-Mail : andyzheng@jdtfuse.com

URL : http://www.joincircuit.com/

Resettable and One-Time Fuse Protection

Resettable fuses and one-time fuses: overcurrent protection. The protection methods used for electronic components fall into two categories, overcurrent protection and overvoltage protection. In everyday products overcurrent protection is the more common of the two, and the use of resettable fuses and one-time fuses is a typical example. This article gives a brief explanation of overcurrent protection.
 
 
Literature on the operating principle of fuses has been abundant for decades, and most people are already thoroughly familiar with it. The actual process by which a resettable fuse delivers overcurrent circuit protection, however, is still not clearly understood, and its advantages have yet to be explored in depth. So far, the accepted view is that a resettable fuse is a polymer-based self-resetting device that can limit current. (Related reading: Wholesale SMD resettable fuses in Shenzhen)
 
 
This article on overcurrent protection with resettable and one-time fuses discusses resettable fuses made from conductive polymer base materials. The polymer material contains many carbon black particles that act as conductive pathways. Resistance is adjusted by changing the carbon black content of the mixture. Heat makes the polymer expand, which moves the carbon black particles apart, so conductivity falls and resistance rises.
 
 
The purpose of a resettable fuse is to limit a potentially harmful overload current to a safe range. Specifically, excessive current through the device increases internal heat generation (I2R), which raises the temperature of the resettable fuse and therefore its resistance.
 
 
Before an over-temperature condition occurs, the resistance of a resettable fuse is usually only a small part of the total circuit impedance. The resistance rise of a polymer resettable fuse is non-linear, and this relatively large resistance reduces or limits the circuit current to a safe range. The transition from low resistance to high resistance is called the “trip point”. (Recommended reading: Detailed product information on leaded resettable fuses)
 
 
Heat produced by the limited current flowing through the higher resistance keeps the resettable fuse at a high temperature, which keeps its resistance high. This thermal equilibrium is maintained until the circuit is powered down and the resettable fuse gradually cools and its resistance falls.
 
 
Overcurrent protection with resettable fuses and one-time fuses — the basic principle behind the self-resetting function of a resettable fuse is that a rise in temperature causes resistance to increase, and vice versa.
 
 
A resettable fuse recovers, or returns to its low-resistance state, when power is removed from the circuit and the device cools down. After that, the component is ready to respond to any future overload. If the cause of the overcurrent problem is removed, the resistance stays low; but if overcurrent occurs again, the device switches back to its high-resistance state. (Recommended reading: How to choose between fuses and resettable fuses)