Shenzhen JDT Fuse Industrial Co.,Ltd
Phone : 0755-8830-8258
Postcode : 518129
E-Mail : andyzheng@jdtfuse.com
URL : http://www.joincircuit.com/
What to Do When the Fuse Blows at Power-On
What should you do when the fuse blows as you switch the power on? In daily life we often run into this problem: appliances tend to fail at the moment a switch is turned on. Once we have confirmed that the fault lies in the fuse, how should we deal with it?
In general, a blown fuse indicates a problem in the internal circuit of the power supply. At that point you need to locate the exact point of failure.
Because a switching power supply works at high voltage and high current, fluctuations and surges in the mains voltage can make the current inside the supply rise for an instant and blow the fuse. Focus on the rectifier diodes, the high-voltage filter electrolytic capacitors and the inverter power switching transistors at the input of the supply, and check whether any of these components has broken down, opened or been damaged.
SMD fuse
If the fuse has indeed blown, first inspect the components on the circuit board for signs of scorching or electrolyte leakage. If nothing of the kind is found, use a multimeter to check whether the switching transistor has broken down or is short-circuited.
Note in particular: never simply replace a faulty component and switch the unit straight back on, because other high-voltage components may still be faulty and can damage the replacement part. Only after every high-voltage component in that circuit has been fully checked and measured can a blown-fuse fault be cleared completely. (Recommended article: Relationship Between the Maximum Safe Current and the Fusing Current of a Fuse)
That is a brief summary of what to do when the fuse blows as you switch the power on. If anything is still unclear, please leave a message for us on the Contact Us page and we will reply as soon as possible.