Miniature fuse selection: what should be considered—when selecting a miniature fuse, people usually choose it according to UL requirements, but that is only the basis. What other factors should be considered? Let's take a look.
When selecting a miniature fuse, the following points should be considered. Once the parameters of the circuit in use are known, choose the fuse according to the aspects below: normal operating current, opening current (the current and the time at which the fuse is expected to open), open-circuit voltage, short-circuit current, inrush current (the current, duration and number of pulses that are not interrupted) and ambient temperature.
(1) Normal operating current: first we must know the normal current flowing through the fuse in the circuit in use. As a rule a derating margin is set in advance, and the fuse is then selected according to the following principle: the normal operating current must be less than the rated current multiplied by the derating factor. (Related reading: How to Select a Fuse: Selection Principles)
(2) Opening current: according to UL requirements, a fuse should open quickly at twice its rated current. In most cases, however, to ensure reliable opening we recommend an opening current greater than 2.5 times the rated current. If opening time matters, the time-current characteristic curves provided by the manufacturer must also be consulted.
(3) Open-circuit voltage: the open-circuit voltage should generally be lower than the rated voltage. For example, using a fuse rated at DC 24 V in a 100 V AC circuit may ignite or rupture the fuse.
(4) Short-circuit current: the maximum current that flows when the circuit is shorted is called the short-circuit current. Every fuse has a specified rated breaking capacity, and when selecting a fuse we must take care that the short-circuit current does not exceed the rated breaking capacity. A fuse with too low a breaking capacity may rupture or cause a fire. (Recommended reading: How to Choose Between a Fuse and a Resettable Fuse)
(5) Inrush current: observe the waveform of the inrush current (the pulse current waveform) and calculate its energy using the I2t value (joule integral). Inrush currents of different magnitude and number affect a fuse differently. The ratio of the I2t of the inrush current to the melting I2t for a single pulse determines how many inrush pulses the fuse can withstand.
What should be considered when selecting a miniature fuse—the points above are the factors to take into account when selecting a miniature fuse. If anything is still unclear, please leave a message on our Contact Us page and we will reply as soon as possible. (Further reading: Is Mobile Phone Radiation Dangerous? When a Phone Becomes a "Grenade")