Hold current 0.75A, maximum voltage 6V, 1206 package. For 0.75A loads on 5V buses. Post-trip resistance 0.40Ω, breaking capacity 100A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 0.75 A |
| Trip current | 1.5 A |
| Maximum voltage | 6 V |
| Maximum fault current | 100 A |
| Initial resistance | 0.1 Ω |
| Post-trip max resistance | 0.4 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.4 W |
| Package | 1206 SMD (3216 mm) |
Its place is a 5V bus such as a USB port, where a surge to 5.5V is still in range. Do not use it on a 12V input port; it is overvoltage as soon as power is applied. For 0.75A in a 12V system, choose MF-MSMF075, 13.2V/100A. For a 24V system, choose MF-MSMF075/24, rated 24V with breaking capacity down to 40A.
Post-trip resistance is 0.40Ω maximum, a 0.30V drop at 0.75A, 6% of a 5V rail. Power is 0.30V×0.75A=0.23W against a 0.40W dissipation rating. Self-heating takes more than half of that, and a higher ambient pulls the hold current down. On a board carrying 0.75A on the 5V rail, do not skimp on pad and copper area.