Hold current 1.10A, maximum voltage 6V, 1206 package. For 1A-level loads and USB ports on 5V supply rails. Post-trip resistance 0.20Ω, breaking capacity 100A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 1.1 A |
| Trip current | 2.2 A |
| Maximum voltage | 6 V |
| Maximum fault current | 100 A |
| Initial resistance | 0.06 Ω |
| Post-trip max resistance | 0.2 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.6 W |
| Package | 1206 SMD (3216 mm) |
A 1.10A load usually sits on a 5V rail, where the 6V rating is enough. Equipment fed from a 12V adapter must use a higher-rated part. For 12V use MF-MSMF110/16, 16V/100A, R1max 0.21Ω. For 24V use MF-MSMF110/24X, breaking capacity down to 20A, R1max 0.18Ω.
New condition is 0.060Ω, a 0.066V drop at 1.10A. After trip the limit is 0.200Ω, a 0.22V drop, 4.4% of a 5V rail and 6.7% of a 3.3V rail. That ratio is the smallest in 1206; 150 is 4.3x and 200 is 4.25x. If the downstream is sensitive to 0.22V, size the position ahead of the regulator on the post-trip value.
150 is 1.50A/6V/0.13Ω, 0.07Ω lower than this part. At a 1.00A load this part has 10% margin and 150 has 50%. The absolute trip currents are 2.20A and 3.00A. If the supply delivers at most 2.5A, 150 never reaches its 3.00A trip point.