Hold current 0.10A, maximum voltage 15V, 0805 package. For milliampere-level sensing and signal circuits in 12V systems. Post-trip resistance 7.50Ω, breaking capacity 40A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 0.1 A |
| Trip current | 0.3 A |
| Maximum voltage | 15 V |
| Maximum fault current | 40 A |
| Initial resistance | 1 Ω |
| Post-trip max resistance | 7.5 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.5 W |
| Package | 0805 SMD (2012 mm) |
12V lead-acid charging reaches 13.8V, leaving 1.2V of margin on 15V. A 24V bus at 28.8V goes straight past the rating; breakdown is followed by an open. For 0.10A on 24V, move to MF-MSMF010, the 1812 60V/40A part. Its R1max is 15.0Ω, twice this part, so the circuit impedance has to be recalculated.
New condition is 1.00Ω, a 0.10V drop at 0.10A. After trip and recovery the limit is 7.50Ω, a 0.75V drop at the same current. That is 15% of a 5V system and 6.3% of a 12V system. This step has the highest resistance of the four 0805 parts and suits high-impedance circuits only.
The 15V 010X is 7.50Ω and the 9V 020X is 3.50Ω. The 6V 035X is 1.20Ω and 075X is 0.35Ω. Want 12V or more of rating and this step's drop comes with it. In a 12V system the 0.75V loss has to be absorbed by the downstream regulator.