Hold current 2.00A, maximum voltage 6V, 1206 package. For 2A loads on 5V buses. Post-trip resistance 0.085Ω, breaking capacity 100A. This is the highest-current step in the 1206 line; recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 2 A |
| Trip current | 4 A |
| Maximum voltage | 6 V |
| Maximum fault current | 100 A |
| Initial resistance | 0.02 Ω |
| Post-trip max resistance | 0.085 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.7 W |
| Package | 1206 SMD (3216 mm) |
2.00A hold current with a 6V rating fits 5V supply rails only. Add this part to a 12V bus and it breaks down at power-up, taking the whole downstream load down. For 2.00A at 12V, switch to MF-SM200, 15V/100A, R1max 0.125Ω. That part is the SM package, so its board footprint differs from 1206.
Post-trip resistance is 0.085Ω maximum, a 0.170V drop at 2.00A, 3.4% of 5V. Power is 0.170V×2.00A=0.34W against a 0.70W dissipation rating. Running 2A in a small package makes pad and copper area the deciding factor for temperature rise. With too little copper the hold current falls early and the 2.00A rating cannot be used in full.