Hold current 0.35A, maximum voltage 6V, 0805 package. For 0.35A loads in 5V systems. Post-trip resistance 1.20Ω, breaking capacity 40A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 0.35 A |
| Trip current | 0.75 A |
| Maximum voltage | 6 V |
| Maximum fault current | 40 A |
| Initial resistance | 0.25 Ω |
| Post-trip max resistance | 1.2 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.5 W |
| Package | 0805 SMD (2012 mm) |
This part sits on a 5V rail, where 6V covers fast-charge transients. On a 12V input terminal it is overvoltage at power-up; breakdown is followed by an open. For 0.35A at 12V, move to the 1206 MF-NSMF035X, rated 16V. That part has only 20A breaking capacity against 40A here, so the swap halves it.
Post-trip resistance is 1.20Ω maximum, a 0.42V drop at 0.35A, 8.4% of 5V. The 0603 MF-FSMF035X is 1.40Ω, a 0.49V drop. One package size up buys 0.07V, which does hold at this step. In a 3.3V system 0.42V is still 13%, so check the downstream threshold.
075X is 0.75A hold, 1.50A trip, R1max 0.35Ω. At a 0.30A load, 035X has 17% margin and 075X has 150%. 0.35Ω at 0.75A is a 0.26V drop, 0.16V below this part. If the supply cannot deliver 1.50A, 075X will not trip.