Hold current 0.75A, maximum voltage 6V, 0805 package. For 0.75A loads on 5V buses. Post-trip resistance 0.35Ω, breaking capacity 40A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 0.75 A |
| Trip current | 1.5 A |
| Maximum voltage | 6 V |
| Maximum fault current | 40 A |
| Initial resistance | 0.09 Ω |
| Post-trip max resistance | 0.35 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.6 W |
| Package | 0805 SMD (2012 mm) |
A 5V rail with a 0.75A load is inside the 6V rating, transients included. Fit this part on 12V and it breaks down at power-up, cutting the downstream load. For 0.75A at 12V, move to the 1812 MF-MSMF075, 13.2V/100A. Its R1max is 0.45Ω, 0.10Ω above this part, a 0.34V drop.
Post-trip resistance is 0.35Ω maximum, a 0.26V drop at 0.75A, 5.2% of 5V. Power is 0.26V×0.75A=0.20W against a 0.60W dissipation rating. Self-heating is 30%, and the pads are one size up from 0603, so cooling is adequate. Neither drop nor temperature rise is the limit here; the 6V rating is.
The four 0805 steps stop at this 0.75A part. For 1.10A, switch to the 1210 MF-USMF110, 6V/40A. Its R1max is 0.21Ω, 0.14Ω below this part, a 0.23V drop. Footprint grows from 0805 to 1210, so the board has to be laid out again.