≡ Param Finder by package / current / voltage

Hold current 0.30A. Maximum voltage 60V. SM package. For overcurrent protection of instrument power supplies and communication interfaces. Post-trip resistance 4.8Ω. Breaking capacity 40A. Automatic recovery after fault removal.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, SM package
Voltage:60 V; Current:hold 0.3 A; trip 0.6 A.

Specifications

ParameterValue
Hold current0.3 A
Trip current0.6 A
Maximum voltage60 V
Maximum fault current40 A
Initial resistance0.9 Ω
Post-trip max resistance4.8 Ω
Trip current / time— A / — s
Dissipated power1.7 W
PackageSM package

Selection Notes

1. 60V rating covers 48V, but 40A breaking capacity cannot handle a large supply

A shorted 0.30A load often draws over 100A from the supply. This part breaks at most 40A. The rest must be handled by the upstream breaker or fuse. Above 40A of prospective short-circuit current, this part cannot break the fault alone. Keep the upstream fuse in the circuit.

2. One trip and reset raises the drop to 1.44V

Fresh resistance is 0.9Ω, giving 0.27V at 0.30A. After a trip and reset the limit is 4.8Ω, giving 1.44V at the same current. On a 5V rail that 1.44V is nearly 30 percent, and downstream chips brown out and reset. Where operation must continue after a trip, recalculate margin at 1.44V.

3. The 1206 0.35A part tops out at 16V, with much lower drop

MF-NSMF035 holds 0.35A, is rated 6V, breaks 100A, and has 1.2Ω post-trip resistance. Drop at 0.35A is 0.42V, about 30 percent of this part's 1.44V. Circuits above 12V need the 60V SM part; a 5V rail saves drop with the 1206.