Hold current 0.30A. Maximum voltage 60V. SM package. For overcurrent protection of instrument power supplies and communication interfaces. Post-trip resistance 4.8Ω. Breaking capacity 40A. Automatic recovery after fault removal.
| Parameter | Value |
| Hold current | 0.3 A |
| Trip current | 0.6 A |
| Maximum voltage | 60 V |
| Maximum fault current | 40 A |
| Initial resistance | 0.9 Ω |
| Post-trip max resistance | 4.8 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 1.7 W |
| Package | SM package |
A shorted 0.30A load often draws over 100A from the supply. This part breaks at most 40A. The rest must be handled by the upstream breaker or fuse. Above 40A of prospective short-circuit current, this part cannot break the fault alone. Keep the upstream fuse in the circuit.
Fresh resistance is 0.9Ω, giving 0.27V at 0.30A. After a trip and reset the limit is 4.8Ω, giving 1.44V at the same current. On a 5V rail that 1.44V is nearly 30 percent, and downstream chips brown out and reset. Where operation must continue after a trip, recalculate margin at 1.44V.
MF-NSMF035 holds 0.35A, is rated 6V, breaks 100A, and has 1.2Ω post-trip resistance. Drop at 0.35A is 0.42V, about 30 percent of this part's 1.44V. Circuits above 12V need the 60V SM part; a 5V rail saves drop with the 1206.