Hold current 0.50A. Maximum voltage 60V. SM package. For fan and relay circuits in 48V communication equipment. Post-trip resistance 1.4Ω. Breaking capacity 40A. Automatic recovery after fault removal.
| Parameter | Value |
| Hold current | 0.5 A |
| Trip current | 1 A |
| Maximum voltage | 60 V |
| Maximum fault current | 40 A |
| Initial resistance | 0.35 Ω |
| Post-trip max resistance | 1.4 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 1.7 W |
| Package | SM package |
A 72V DC rail sits at 72V in normal operation, with higher peaks. Voltage above 60V across this part causes breakdown; after breakdown the element opens and the whole downstream circuit loses power. On a 48V system the 60V rating leaves 12V of headroom, which is enough. For 72V at the same current, use the MF-RX series, where all six parts are 72V.
Fresh resistance is 0.35Ω for 0.18V. After a trip and reset the limit is 1.4Ω, or 0.70V. On a 48V rail 0.70V is only 1.5 percent and does not affect operation. On a 12V auxiliary supply 0.70V is 5.8 percent, so downstream modules need input range reserved for it.