Hold current 0.75A. Maximum voltage 30V. SM package. For overcurrent protection on 24V industrial control boards and security equipment. Post-trip resistance 1.0Ω. Breaking capacity 80A. Automatic recovery after fault removal.
| Parameter | Value |
| Hold current | 0.75 A |
| Trip current | 1.5 A |
| Maximum voltage | 30 V |
| Maximum fault current | 80 A |
| Initial resistance | 0.23 Ω |
| Post-trip max resistance | 1 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 1.7 W |
| Package | SM package |
| Model | Vmax | R1max | Package | Note |
| MF-SM075/60 | 60 V | 1 Ω | SM package |
Both hold 0.75A and trip at 1.50A, with resistances of 0.23Ω and 1.0Ω. This part is rated 30V and breaks 80A; the one with 60 after the slash is rated 60V and breaks only 10A. The number after the slash is the voltage rating, not a revision. Buying this part for a 24V rail means breakdown at the first voltage spike. Buying the 075 for a 48V rail gives the same breakdown.
Fresh resistance is 0.23Ω for 0.17V at 0.75A. After reset the limit is 1.0Ω, or 0.75V. On a 24V system 0.75V is 3 percent and acceptable. On a 5V system it is 15 percent, so downstream logic chips need their input threshold recalculated against 4.25V.
MF-PSMF075X holds 0.75A, breaks 40A, and has 0.35Ω post-trip resistance for 0.26V drop. This part's 1.0Ω is nearly three times that, adding 0.49V of drop. A 5V board is better off with the 0805; only a 12V circuit requires this 30V SM part.