≡ Param Finder by package / current / voltage

Hold current 0.75A. Maximum voltage 60V. SM package. For overcurrent protection of 48V power modules and low-current loads. Post-trip resistance 1.0Ω. Breaking capacity 10A. Automatic recovery after fault removal.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, SM package
Voltage:60 V; Current:hold 0.75 A; trip 1.5 A.

Specifications

ParameterValue
Hold current0.75 A
Trip current1.5 A
Maximum voltage60 V
Maximum fault current10 A
Initial resistance0.23 Ω
Post-trip max resistance1 Ω
Trip current / time— A / — s
Dissipated power1.7 W
PackageSM package

Same-Package Alternatives

ModelVmaxR1maxPackageNote
MF-SM07530 V1 ΩSM package

Selection Notes

1. Voltage rating doubles, breaking capacity drops from 80A to 10A

The 60 after the slash is the voltage rating, not a revision. The same-current MF-SM075 is rated 30V and breaks 80A; this part is rated 60V and breaks only 10A. Short-circuit current on a 24V supply is often above 30A, and the excess cannot be broken, so the arc burns until upstream protection acts. A higher-voltage part solves breakdown but trades away breaking capacity. Read both numbers together.

2. A 48V circuit does not care about 0.75V; a 5V circuit does

Fresh resistance is 0.23Ω for 0.17V. After reset the limit is 1.0Ω, or 0.75V at 0.75A. On a 48V system this 0.75V is 1.6 percent and downstream design needs no change. Move it to a 5V auxiliary supply and 0.75V takes 15 percent, so chips reset easily.

3. At 60V, SM030 and SM050 break 40A

In the SM series the 0.75A step pairs 60V only with 10A breaking capacity. If 60V is needed and short-circuit current is a concern, drop to the 0.50A step and use MF-SM050, which breaks 40A. If the load truly needs 0.75A, add a fuse stage in the circuit.