Hold current 1.10A. Maximum voltage 30V. SM package. For overcurrent protection of 24V industrial power supplies and security mainboards. Post-trip resistance 0.48Ω. Breaking capacity 80A. Automatic recovery after fault removal.
| Parameter | Value |
| Hold current | 1.1 A |
| Trip current | 2.2 A |
| Maximum voltage | 30 V |
| Maximum fault current | 80 A |
| Initial resistance | 0.12 Ω |
| Post-trip max resistance | 0.48 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 1.7 W |
| Package | SM package |
| Model | Vmax | R1max | Package | Note |
| MF-SM100/33 | 33 V | 0.41 Ω | SM package |
Both hold 1.10A and trip at 2.20A, with 0.12Ω fresh resistance. This part is rated 30V and breaks 80A; the 100/33 is rated 33V and breaks 40A. Buying the 100/33 for a 24V circuit gives enough breaking capacity, but 3V of extra voltage rating means nothing; neither part works on a 48V circuit. The biggest trap is buying this part for a 36V supply, which breaks down at power-up.
Fresh resistance is 0.12Ω for 0.13V. After reset the limit is 0.48Ω, or 0.53V. That is 10 percent on a 5V system and 16 percent on a 3.3V system. A 3.3V logic circuit must allow 0.53V when calculating the minimum downstream input voltage.
MF-R110 holds 1.10A, is rated 30V, breaks 40A, and has 0.27Ω post-trip resistance for 0.30V drop. This part's 0.48Ω is 1.8 times that. Where through-hole is allowed, use MF-R110 for its larger heat-dissipating body; surface-mount assembly leaves only this part.