≡ Param Finder by package / current / voltage

Hold current 1.10A. Maximum voltage 33V. SM package. For overcurrent protection of 28V automotive modules and communication power supplies. Post-trip resistance 0.41Ω. Breaking capacity 40A. Automatic recovery after fault removal.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, SM package
Voltage:33 V; Current:hold 1.1 A; trip 2.2 A.

Specifications

ParameterValue
Hold current1.1 A
Trip current2.2 A
Maximum voltage33 V
Maximum fault current40 A
Initial resistance0.12 Ω
Post-trip max resistance0.41 Ω
Trip current / time— A / — s
Dissipated power1.7 W
PackageSM package

Same-Package Alternatives

ModelVmaxR1maxPackageNote
MF-SM10030 V0.48 ΩSM package

Selection Notes

1. The 33 after the slash is the voltage rating, and breaking capacity falls to 40A

The same-current MF-SM100 is rated 30V and breaks 80A; this part is rated 33V and breaks 40A. Three volts more rating, half the breaking capacity. Use this part on 28V rails and MF-SM100 on 12V rails. Where upstream prospective current is 60A, this part cannot break the arc.

2. Lower resistance limit than the 100, with 0.45V drop

Fresh resistance is 0.12Ω for 0.13V. After reset the limit is 0.41Ω, or 0.45V at 1.10A. The same-current MF-SM100 is 0.48Ω and 0.53V, so this part is 0.08V lower. Choose it where drop is tight, at the cost of breaking capacity falling from 80A to 40A.

3. For 1.10A and 33V in surface mount, this is the only part

The 60V step of SM surface mount covers only 0.30A, 0.50A and 0.75A, none of which carries 1.10A. The MF-RX series reaches 72V but is all DIP through-hole. For surface-mount assembly at 33V or above, this page offers no alternative.

Up Page: