Hold current 1.10A. Maximum voltage 33V. SM package. For overcurrent protection of 28V automotive modules and communication power supplies. Post-trip resistance 0.41Ω. Breaking capacity 40A. Automatic recovery after fault removal.
| Parameter | Value |
| Hold current | 1.1 A |
| Trip current | 2.2 A |
| Maximum voltage | 33 V |
| Maximum fault current | 40 A |
| Initial resistance | 0.12 Ω |
| Post-trip max resistance | 0.41 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 1.7 W |
| Package | SM package |
| Model | Vmax | R1max | Package | Note |
| MF-SM100 | 30 V | 0.48 Ω | SM package |
The same-current MF-SM100 is rated 30V and breaks 80A; this part is rated 33V and breaks 40A. Three volts more rating, half the breaking capacity. Use this part on 28V rails and MF-SM100 on 12V rails. Where upstream prospective current is 60A, this part cannot break the arc.
Fresh resistance is 0.12Ω for 0.13V. After reset the limit is 0.41Ω, or 0.45V at 1.10A. The same-current MF-SM100 is 0.48Ω and 0.53V, so this part is 0.08V lower. Choose it where drop is tight, at the cost of breaking capacity falling from 80A to 40A.
The 60V step of SM surface mount covers only 0.30A, 0.50A and 0.75A, none of which carries 1.10A. The MF-RX series reaches 72V but is all DIP through-hole. For surface-mount assembly at 33V or above, this page offers no alternative.