Hold current 1.50A. Maximum voltage 15V. SM package. For overcurrent protection of 12V motor drives and relay circuits. Post-trip resistance 0.25Ω. Breaking capacity 100A. Automatic recovery after fault removal.
| Parameter | Value |
| Hold current | 1.5 A |
| Trip current | 3 A |
| Maximum voltage | 15 V |
| Maximum fault current | 100 A |
| Initial resistance | 0.06 Ω |
| Post-trip max resistance | 0.25 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 1.9 W |
| Package | SM package |
| Model | Vmax | R1max | Package | Note |
| MF-SM150/33 | 33 V | 0.23 Ω | SMD package |
A 12V lead-acid battery charges to 14.4V, which this part still holds. Automotive 24V systems and industrial 24V supplies reach 28V and above, so voltage across this part causes breakdown, and after breakdown the element opens. A 24V circuit needs MF-SM150/33, rated 33V. Both parts carry the same current; choose by the number after the slash.
Fresh resistance is 0.06Ω for 0.09V. After reset the limit is 0.25Ω, or 0.38V at 1.50A. At the moment of trip it dissipates 1.9W, and the heat runs from both terminals into the pads; size the pads as the datasheet drawing shows. Do not glue the underside of the body down, because the material expands when heated.
MF-SM150/33 holds 1.50A, is rated 33V, breaks 40A, and has 0.23Ω post-trip resistance. A 12V circuit can see 100A of short-circuit current, so use this part; a 24V circuit can only use the /33. Voltage rating and breaking capacity run opposite on these two, so picking one number means missing the other.