≡ Param Finder by package / current / voltage

Hold current 1.50A. Maximum voltage 15V. SM package. For overcurrent protection of 12V motor drives and relay circuits. Post-trip resistance 0.25Ω. Breaking capacity 100A. Automatic recovery after fault removal.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, SM package
Voltage:15 V; Current:hold 1.5 A; trip 3 A.

Specifications

ParameterValue
Hold current1.5 A
Trip current3 A
Maximum voltage15 V
Maximum fault current100 A
Initial resistance0.06 Ω
Post-trip max resistance0.25 Ω
Trip current / time— A / — s
Dissipated power1.9 W
PackageSM package

Same-Package Alternatives

ModelVmaxR1maxPackageNote
MF-SM150/3333 V0.23 ΩSMD package

Selection Notes

1. With a 15V rating, a 12V system has only 3V of margin

A 12V lead-acid battery charges to 14.4V, which this part still holds. Automotive 24V systems and industrial 24V supplies reach 28V and above, so voltage across this part causes breakdown, and after breakdown the element opens. A 24V circuit needs MF-SM150/33, rated 33V. Both parts carry the same current; choose by the number after the slash.

2. 0.38V drop, and all 1.9W leaves through the two terminals

Fresh resistance is 0.06Ω for 0.09V. After reset the limit is 0.25Ω, or 0.38V at 1.50A. At the moment of trip it dissipates 1.9W, and the heat runs from both terminals into the pads; size the pads as the datasheet drawing shows. Do not glue the underside of the body down, because the material expands when heated.

3. 100A breaking capacity; the same-current /33 is only 40A

MF-SM150/33 holds 1.50A, is rated 33V, breaks 40A, and has 0.23Ω post-trip resistance. A 12V circuit can see 100A of short-circuit current, so use this part; a 24V circuit can only use the /33. Voltage rating and breaking capacity run opposite on these two, so picking one number means missing the other.