Hold current 1.80A. Maximum voltage 33V. SM package. For overcurrent protection of 24V automotive and industrial control modules. Post-trip resistance 0.15Ω. Breaking capacity 40A. Automatic recovery after fault removal.
| Parameter | Value |
| Hold current | 1.8 A |
| Trip current | 3.6 A |
| Maximum voltage | 33 V |
| Maximum fault current | 40 A |
| Initial resistance | 0.04 Ω |
| Post-trip max resistance | 0.15 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 1.9 W |
| Package | SM package |
The 60V SM parts come in only three current steps, 0.30A, 0.50A and 0.75A, none reaching 1.80A. The 33 after the slash is the voltage rating, so a 48V system across this part breaks it down. For 1.80A at 48V the only option is MF-RX185/72, which is DIP through-hole.
Fresh resistance is 0.04Ω for 0.072V at 1.80A. After reset the limit is 0.15Ω, or 0.27V. On a 24V circuit 0.27V is 1.1 percent and can be ignored. On a 5V circuit it is 5.4 percent, and downstream parts need that margin. At the moment of trip 1.9W lands in the body, so do not place tall components around it.
MF-RX185/72 holds 1.85A, is rated 72V, breaks 40A, and has 0.12Ω post-trip resistance for 0.22V drop. Switch to it where circuit voltage exceeds 33V or 72V margin is required. If assembly must be surface mount, this page's part stops at 33V.