Shenzhen JDT Fuse Industrial Co.,Ltd

Phone : 0755-8830-8258

Postcode : 518129

E-Mail : andyzheng@jdtfuse.com

URL : http://www.joincircuit.com/

Resettable Fuse Parameters Explained

A reader writing under the screen name “Southbound Swallow” emailed us: I am a fuse hobbyist and have recently been studying resettable fuses. Some of the common parameters I do not fully understand, so could you explain them in detail? Many readers are in the same position as this friend and have no deep grasp of resettable fuse parameters, so we have collected and organised the answers below.
 
 
The parameters most often quoted for a resettable fuse are the following:
 
Hold current (Ihold): the highest current that can be carried at 25°C in still air without tripping the resistance step. (Related reading: Resettable fuse questions answered)
Trip current (Itrip): the minimum current at which a PTC polymer resettable fuse switches from low resistance to high resistance at 25°C in still air.
Maximum voltage (Vmax): the maximum working voltage of a PTC polymer resettable fuse.
Maximum current (Imax): the maximum current a PTC polymer resettable fuse can withstand.
Typical power dissipation (Pd typ.): the power dissipated by a PTC polymer resettable fuse in the tripped state at 25°C ambient.
Trip time (Ttrip): the maximum time to trip at five times the hold current.
 
 
The table below sets out the application areas for each type of resettable fuse, so that the parameters above are easier to place in context. (Recommended reading: Resettable fuse protection scheme for ATMs)

 
Resettable fuse parameter table

 
Resettable fuse parameter table: application range
 
Parameter application table